952.5-0000010 OM
95
- check and if required tighten the bolts attaching cylinder heads;
- check and if required adjust clearance between the valves and rockers arms;
- check lubrication in all assembly units according to clause 3 of table 5.4. Where
required lubricate or replace the lubricant;
- check and if necessary restore hermiticity of the air cleaner and inlet line;
- control engine running, steering, brakes, operation controls, lighting and warning
systems;
3.5 Emergency actions
3.5.1 To stop the tractor immediately, sharply depress clutch and brake pedals.
3.5.2 For emergency stop of the engine turn the key of the starter and instrument
switch from “I” position to “0” position according to the diagram provided in figure 2.2.2.
3.5.3. In case of an accident immediately stop the engine, engage tractor brakes, deacti-
vate accumulator batteries and get off the tractor through one of emergency exits, having
opened left or right cab door, depending on the tractor position, or rear screen, or the roof.
If it is not possible to open the emergency exits, break front or rear screen, or one of the
lateral screens with a heavy subject at hand and leave the tractor cab.
Note – Emergency exit allocation is given in subsection 2.22 “Cab locks and han-
dles”.
3.5.4 In case the engine crankshaft speeds up excessively, kill the engine and brake the
tractor immediately.
3.5.5 In case a fire bed occurs, stop the engine, brake the tractor, turn off the accumulator
battery switch. Pour some sand onto the fire bed, cover with canvas cloth, sackcloth or
other dense texture. Use a carbon-dioxide fire extinguisher. Do not pour water over burn-
ing fuel and oil.
Содержание BELARUS 952.5
Страница 1: ...BELARUS 9 5 2 5 952 5 0000010B OM OPERATOR S MANUAL 2013...
Страница 188: ...952 5 0000010 OM 188 Service bulletins...