669 – AL ProActA Yellow
Yellow alarm.
Associated parameter 1.4550.093
Cause
Corrective action
An internal combined alarm in
throttle A was detected.
u
An exact fault designation is transmitted via CAN bus to the
genset control system.
670 – AL ProActB Yellow
Yellow alarm.
Associated parameter 1.4550.193
Cause
Corrective action
An internal combined alarm in
throttle B was detected.
u
An exact fault designation is transmitted via CAN bus to the
genset control system.
671 – AL NOxA Yellow
Yellow alarm.
Associated parameter 1.4560.093
Cause
Corrective action
An internal combined alarm at
NOx sensor A was detected.
u
An exact fault designation is transmitted via CAN bus to the
genset control system.
672 – AL NOxB Yellow
Yellow alarm.
Associated parameter 1.4560.193
Cause
Corrective action
An internal combined alarm at
NOx sensor B was detected.
u
An exact fault designation is transmitted via CAN bus to the
genset control system.
675 – AL GET Red
Red alarm.
Associated parameter 1.4510.991
Cause
Corrective action
An internal combined alarm in
knock control was detected.
u
An exact fault designation is transmitted via CAN bus to the
genset control system.
676 – AL IC92x Red
Red alarm.
Associated parameter 1.4520.991
Cause
Corrective action
An internal combined alarm in
the ignition system was
detected.
u
An exact fault designation is transmitted via CAN bus to the
genset control system.
MS150121/00E 2015-07
| Troubleshooting | 129
TIM-ID: 0000038612 - 001