118 – LO ECU Power Supply Voltage
Yellow alarm.
Associated parameter 2.0140.921
Cause
Corrective action
Supply voltage too low (limit
value 1).
1. Check supply voltage.
2. Check cabling.
119 – LOLO ECU Power Supply Voltage
Red alarm.
Associated parameter 2.0140.922
Cause
Corrective action
Supply voltage too low (limit
value 2).
1. Check supply voltage.
2. Check cabling.
120 – HI ECU Power Supply Voltage
Yellow alarm.
Associated parameter 2.0140.931
Cause
Corrective action
Supply voltage too high (limit
value 1).
1. Check supply voltage.
2. Check cabling.
121 – HIHI ECU Power Supply Voltage
Red alarm.
Associated parameter 2.0140.932
Cause
Corrective action
Supply voltage too high (limit
value 2).
1. Check supply voltage.
2. Check cabling.
122 – HI T-ECU
Yellow alarm.
Associated parameter 2.0132.921
Cause
Corrective action
Electronics temperature too high
(limit value 1).
u
Provide improved cooling for ECU. Reduce room temperature,
check air flow to ADEC.
180 – AL CAN1 Node Lost
Yellow alarm.
Associated parameter 2.0500.680
Cause
Corrective action
Bus node (SAM or EMU) lost on
CAN bus 1.
u
Check operation of bus stations and cabling. Buses (CAN bus 1
and CAN bus 2) are redundant.
106 | Troubleshooting | MS150121/00E 2015-07
TIM-ID: 0000038612 - 001