Consumption
Number of cylinders
16
Lube oil consumption after 1000 h runtime
g/kWh
0.3
Table 22: Consumption
Model-related data (basic design)
Number of cylinders
16
Operating method: Four-stroke cycle, Otto engine, single-acting
X
Combustion method: Mixture charging, spark ignition
X
Number of cylinders
16
Cylinder arrangement: V-angle
Degrees (°)
90
Bore
mm
170
Stroke
mm
210
Displacement, cylinder
Liters
4.77
Displacement, total
Liters
76.27
Compression ratio
10.5
Standard housing connecting flange (engine main PTO)
SAE
00
Table 23: Model-related data (basic design)
Coolant system (HT circuit, referenced to max. power without HT heat extraction)
Number of cylinders
16
Coolant temperature (at engine connection: outlet to cooling equipment)
(w/o antifreeze)
A
°C
90
Coolant temperature (at engine connection: inlet from cooling equipment
(w/o antifreeze)
A
°C
78
Coolant temperature after engine, alarm
R
°C
95
Coolant temperature after engine, shutdown
L
°C
98
Coolant temperature to enable load application, min.
L
°C
40
Coolant antifreeze content, max.
L
%
50
Coolant pump: Volumetric flow
L
m³/h
80
Filling pressure in cooling system (cold)
R
bar
0.5
Pressure in cooling system, max.
L
bar
6.0
Pressure loss over engine with maximum flow rate
bar
3.1
Thermostat: Starts to open
R
°C
68
Thermostat: Opening stops (thermostat fully open and bypass closed
A
°C
78
Table 24: Coolant system (HT circuit, referenced to max. power without HT heat extraction)
Coolant system (LT circuit, referenced to max. power without HT heat extraction)
Number of cylinders
16
Coolant temperature before mixture cooler (at engine connection: inlet
from cooling equipment (w/o antifreeze)
A
°C
53
Coolant antifreeze content, max.
L
%
50
MS150121/00E 2015-07
| Product Summary | 31
TIM-ID: 0000062776 - 001