![MTU 16V4000Lx2x Скачать руководство пользователя страница 61](http://html1.mh-extra.com/html/mtu/16v4000lx2x/16v4000lx2x_operating-instructions-manual_1852689061.webp)
112404 – LO T-Exhaust A4
Yellow alarm. Initiated by EMU.
Cause
Corrective action
Individual exhaust gas
temperature of this cylinder is
too low in comparison with
weighted average.
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 145).
4. Check valve drive.
112405 – LO T-Exhaust A5
Yellow alarm. Initiated by EMU.
Cause
Corrective action
Individual exhaust gas
temperature of this cylinder is
too low in comparison with
weighted average.
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 145).
4. Check valve drive.
112406 – LO T-Exhaust A6
Yellow alarm. Initiated by EMU.
Cause
Corrective action
Individual exhaust gas
temperature of this cylinder is
too low in comparison with
weighted average.
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 145).
4. Check valve drive.
112407 – LO T-Exhaust A7
Yellow alarm. Initiated by EMU.
Cause
Corrective action
Individual exhaust gas
temperature of this cylinder is
too low in comparison with
weighted average.
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 145).
4. Check valve drive.
112408 – LO T-Exhaust A8
Yellow alarm. Initiated by EMU.
Cause
Corrective action
Individual exhaust gas
temperature of this cylinder is
too low in comparison with
weighted average.
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 145).
4. Check valve drive.
MS150121/00E 2015-07
| Troubleshooting | 61
TIM-ID: 0000062618 - 001