1.4510.193 – Knock Sensor Error A2
Red alarm. Initiated by anti-knock control.
Cause
Corrective action
No signal from this knock sensor.
1. Check cabling (→ Page 202).
2. Check sensor (tightening torque, damage), replace as necessary
1.4510.194 – Knock Sensor Error A3
Red alarm. Initiated by anti-knock control.
Cause
Corrective action
No signal from this knock sensor.
1. Check cabling (→ Page 202).
2. Check sensor (tightening torque, damage), replace as necessary
1.4510.195 – Knock Sensor Error A4
Red alarm. Initiated by anti-knock control.
Cause
Corrective action
No signal from this knock sensor.
1. Check cabling (→ Page 202).
2. Check sensor (tightening torque, damage), replace as necessary
1.4510.196 – Knock Sensor Error A5
Red alarm. Initiated by anti-knock control.
Cause
Corrective action
No signal from this knock sensor.
1. Check cabling (→ Page 202).
2. Check sensor (tightening torque, damage), replace as necessary
1.4510.197 – Knock Sensor Error A6
Red alarm. Initiated by anti-knock control.
Cause
Corrective action
No signal from this knock sensor.
1. Check cabling (→ Page 202).
2. Check sensor (tightening torque, damage), replace as necessary
1.4510.198 – Knock Sensor Error A7
Red alarm. Initiated by anti-knock control.
Cause
Corrective action
No signal from this knock sensor.
1. Check cabling (→ Page 202).
2. Check sensor (tightening torque, damage), replace as necessary
80 | Troubleshooting | MS150104/03E 2017-09
TIM-ID: 0000038611 - 005