112410 – LO T-Exhaust A10
Yellow alarm. Initiated by EMU.
Cause
Corrective action
Exhaust gas temperature of this
cylinder is too low in comparison
with weighted average.
1. Check igniter.
2. Check emission values (→ Page 47).
3. Check ignition timing (→ Page 176).
4. Check valve drive.
5. Check wiring on the ignition rail/ignition coil for thermal and
mechanical damage.
112411 – LO T-Exhaust B1
Yellow alarm. Initiated by EMU.
Cause
Corrective action
Exhaust gas temperature of this
cylinder is too low in comparison
with weighted average.
1. Check igniter.
2. Check emission values (→ Page 47).
3. Check ignition timing (→ Page 176).
4. Check valve drive.
5. Check wiring on the ignition rail/ignition coil for thermal and
mechanical damage.
112412 – LO T-Exhaust B2
Yellow alarm. Initiated by EMU.
Cause
Corrective action
Exhaust gas temperature of this
cylinder is too low in comparison
with weighted average.
1. Check igniter.
2. Check emission values (→ Page 47).
3. Check ignition timing (→ Page 176).
4. Check valve drive.
5. Check wiring on the ignition rail/ignition coil for thermal and
mechanical damage.
112413 – LO T-Exhaust B3
Yellow alarm. Initiated by EMU.
Cause
Corrective action
Exhaust gas temperature of this
cylinder is too low in comparison
with weighted average.
1. Check igniter.
2. Check emission values (→ Page 47).
3. Check ignition timing (→ Page 176).
4. Check valve drive.
5. Check wiring on the ignition rail/ignition coil for thermal and
mechanical damage.
64 | Troubleshooting | MS150104/03E 2017-09