604 – AL Hut Changespeed max.
Yellow alarm.
Associated parameter 2.1210.910
Cause
Corrective action
Excessively rapid change in gas
quality.
u
Check gas system.
606 – AL Double Nodes Lost CAN 1 + 2
Yellow alarm.
Associated parameter 2.0500.691
Cause
Corrective action
Bus node (EMU) lost on CAN bus
1 and 2.
u
Check operation of bus nodes and cabling (→ Page 202).
608 – AL Wiring PWM_CM6
Red alarm.
Associated parameter 1.1041.926
Cause
Corrective action
Wire break or short circuit on
channel PWM_CM6.
u
Check setting at engine governor.
609 – AL Wiring PWM_CM7
Red alarm.
Associated parameter 1.1041.927
Cause
Corrective action
Wire break or short circuit on
channel PWM_CM7.
u
Check cabling to NOx sensor on A side (→ Page 202).
615 – AL EIL Protection
Red alarm.
Associated parameter 2.0610.951
Cause
Corrective action
Response to faulty or manipulated
EIL.
u
Check EIL.
616 – AL EIL Error
Red alarm.
Associated parameter 1.0610.952
Cause
Corrective action
Faulty or manipulated EIL.
u
Check EIL.
MS150104/03E 2017-09
| Troubleshooting | 149
TIM-ID: 0000038612 - 003