112702 – HIHI T-Exhaust A2 (abs)
Red alarm. Initiated by EMU.
Cause
Corrective action
Exhaust gas temperature of this
cylinder is too high.
1. Check emission values (→ Page 47).
2. Check ignition timing (→ Page 176).
3. Check valve drive (exhaust valves do not close).
112703 – HIHI T-Exhaust A3 (abs)
Red alarm. Initiated by EMU.
Cause
Corrective action
Exhaust gas temperature of this
cylinder is too high.
1. Check emission values (→ Page 47).
2. Check ignition timing(→ Page 176).
3. Check valve drive (exhaust valves do not close).
112704 – HIHI T-Exhaust A4 (abs)
Red alarm. Initiated by EMU.
Cause
Corrective action
Exhaust gas temperature of this
cylinder is too high.
1. Check emission values (→ Page 47).
2. Check ignition timing (→ Page 176).
3. Check valve drive (exhaust valves do not close).
112705 – HIHI T-Exhaust A5 (abs)
Red alarm. Initiated by EMU.
Cause
Corrective action
Exhaust gas temperature of this
cylinder is too high.
1. Check emission values (→ Page 47).
2. Check ignition timing (→ Page 176).
3. Check valve drive (exhaust valves do not close).
112706 – HIHI T-Exhaust A6 (abs)
Red alarm. Initiated by EMU.
Cause
Corrective action
Exhaust gas temperature of this
cylinder is too high.
1. Check emission values (→ Page 47).
2. Check ignition timing (→ Page 176).
3. Check valve drive (exhaust valves do not close).
112707 – HIHI T-Exhaust A7 (abs)
Red alarm. Initiated by EMU.
Cause
Corrective action
Exhaust gas temperature of this
cylinder is too high.
1. Check emission values (→ Page 47).
2. Check ignition timing (→ Page 176).
3. Check valve drive (exhaust valves do not close).
MS150104/03E 2017-09
| Troubleshooting | 75
TIM-ID: 0000038611 - 005