679 – AL ProActA Red
Red alarm.
Associated parameter 1.4550.091
Cause
Corrective action
An internal summary alarm in
restrictor flap A was detected.
u
An exact fault designation is transmitted via CAN bus to the genset
control system.
680 – AL ProActB Red
Red alarm.
Associated parameter 1.4550.191
Cause
Corrective action
An internal summary alarm in
restrictor flap B was detected.
u
An exact fault designation is transmitted via CAN bus to the genset
control system.
681 – AL NOxA Red
Red alarm.
Associated parameter 1.4560.091
Cause
Corrective action
An internal summary alarm at NOx
sensor A was detected.
u
An exact fault designation is transmitted via CAN bus to the genset
control system.
682 – AL NOxB Red
Red alarm.
Associated parameter 1.4560.191
Cause
Corrective action
An internal summary alarm at NOx
sensor B was detected.
u
An exact fault designation is transmitted via CAN bus to the genset
control system.
685 – AL Lube Oil Min
Red alarm.
Associated parameter 1.1480.307
Cause
Corrective action
Minimum engine oil filling level
detected.
1. Check engine oil level (→ Page 188).
2. Check replenishment system.
3. Fill oil.
686 – AL Lube Oil Max
Red alarm.
Associated parameter 1.1480.309
Cause
Corrective action
Maximum engine oil filling level
detected.
1. Check engine oil level (→ Page 188).
2. Check replenishment system.
3. Drain oil.
MS150104/03E 2017-09
| Troubleshooting | 157
TIM-ID: 0000038612 - 003