Operating voltage
Rated voltage: 24 VDC
Continuous voltage:
16.5 VDC to 32 VDC
Temporarily restricted operation:
11 VDC to 36 VDC
Residual ripple: Max. 8 V
pp
Power consumption
Max. 30 A
Heat loss
Max. 35 W
Operating temperature range
0 °C to +75 °C
Storage temperature range
–10 °C to +75 °C
Relative air humidity
0% to 95 % condensing
Degree of protection
IP 65 DIN 40 050
Shock
15 g/11 ms semi-sinusoidal shock
Vibration
2 Hz to 13 Hz: X
pp
= ±1.6 mm
25 Hz to 100 Hz: a= ±4 g
100 Hz to 2000 Hz: Electrical noise 1.3 g rms
EMC
DIN EN 50081–2
DIN EN 50082–2
IEC 1000–4–2
IEC 1000–4–3
IEC 1000–4–4
IEC 1000–4–5
IEC 1000–4–6
MS150025/02E 2012-10 | General Information | 27
TIM-ID: 0000009426 - 001