RF Setup Procedure
VFLG
U)
example ScID Value
fixed
blinking
blinking
Error Correction: If you input a wrong value, press
ZERO
to step
back one digit and reenter.
&KQ/
USER
F
TARE
T
TARE
T
TARE
T
TARE
T
TARE
T
TARE
T
TARE
T
1)
With the power on, open the
Comm Setup Menu by
pressing the
TARE
and
USER
keys simultaneously.
The COMM Setup Menu
appears. The first menu
choice is “Print”.
2)
Press
USER
to scroll to the
RF Setup menus.
3)
Press
TARE
to enter the RF
setup menu.
4)
The display reads “OnOff”
Confirm the 8000 RF is on
by pressing
TARE
. If it is off,
use the
USER
key to change
it to on. Then push
TARE
.
Off is only used when the 8000 is
hardwired to a Dyna-Link.
5)
Press
TARE
. Next the “Scid”
(ScaleCore ID) screen is
shown
6)
Press
TARE
. The current
Scid number is shown.
If the offered Scid value is correct,
push
TARE
and jump to step 10.
In this example we’ll enter 3 as an SCID
number. Any value from 1-254 is
acceptable. However, MSI
recommends a value from 20 – 30.
7)
To input the SCID value,
press
USER
to start the
number entry process..
8)
Use
USER
to change the
number, and
TARE
to
enter the number. Add the
next digit by pushing
USER
and scrolling as
required. Repeat this
sequence until the entire
SCID number is entered.
9) Once the entire SCID
value is entered, press
TARE
to finalize the
number.
10) The next RF Setup
parameter is “ChnL”
(Channel). Press
TARE
to
start the number entry
process.
USER
F
USER
F
Press Simultaneously
TARE
T
USER
F
RF Remote Display Option
51
Figure 7-5. RF Setup Menu