6
MSI-4260 Port-A-Weigh Operator’s Manual
1.4 Specifications
Accuracy
±(0.1% +1d). ‘d’ equals one displayable increment.
Resolution
Standard displayed resolution: 2500-3750’d’.
Resolutions to 10000’d’ (non LFT units only) are possible.
Internal A/D resolution 24 bits
Standard
Capacities
lb
500 2000 5000 10000 20000 30000 50000 70000 100000
kg
250 1000 2500 5000 10000 15000 25000 35000 50000
Power
Battery operated, 12V rechargeable sealed lead acid battery pack
(standard Port-A-Weigh Charger).
Up to 100 hours of battery life with Automatic Sleep Mode and
Automatic Power Off
Display
5 digit, large 1.2 in (30.5 mm) numeric red GaAIAs Light Emitting
Diode (LED)
Operating
Temp
-40°F to +122°F (-40°C to +50°C), LFT range -10°C to +40°C
Operating Time
100 hours typical/150 hours max. (depends on operating mode)
Enclosure
NEMA 4/1P65 powder coated alodined cast aluminum
Load Cell
Standard 350 Ω Bridge, MSI Trinocular (>10k lb.)
USER
Programmable multifunction button for use as
TEST, TOTAL, UNIT, PEAK, NET/GROSS, VIEW TOTAL, LEARN
(for RF Remote Control)
CAL
Wire sealed calibration switch (located on the left side of the front
casting).
Initiates full digital calibration procedure.
Auto Zero
Maintenance
Standard, can be disabled internally
Auto-Off Mode
Prolongs battery life by turning POWER off after 15, 30, 45 or 60
minutes (operator determined) of no scale activity
Auto-Sleep
Mode
Prolongs battery life by dimming LED display after 5, 15, or 30
minutes of no activity
Units
kg, lb (other units available with custom calibrations)
Filtering
Selectable:
• OFF, Low (LO)
• Medium (HI-1)
• High (HI-2)
Totalization
Standard: Press button or Automatic; TOTAL weight up to 99999 X
1000 kg or lb
Peak
Uses unfiltered faster reading of A/D (>400 readings per second)
Set Points
Three internal standard Set Points and three ultra bright LEDs on
indicator panel.
Set Point relay options are available, contact factory.
Table 1-1. Specifications