p
8) To enter a calibration
weight other than
capacity, press
USER
. The
display far left digit will
flash zero indicating that
a number should be
entered.
blinking
Error Correction: If you input a wrong
value, press
ZERO
to step back one
digit and reenter.
USER
F
5 times
fixed
blinking
blinking
blinking
blinking
blinking
blinking
fixed
fixed
fixed
3DVV
9) Press the
USER
key to
scroll the number and
the
TARE
key to enter
each digit of the
calibration weight.
In this example, we’ll enter 2500
kg on a 5000 kg capacity scale.
Do not push the
TARE
key two
times in a row until the entire
number is showing..
To add a decimal point, push the
POWER
key while the number is
blinking.
10) When the entire value of
the test weight is displayed
and the weight and scale
are stable, press
TARE
to
finish off the weight entry.
If the resultant cal value is
within limits, the display will
read “PASS” briefly.
11) The display now reads
“Load2”. The 4260
allows multipoint
calibration. If more Cal
Points are desired (up to
3 additional) press
TARE
. If a single point
cal is all that’s needed,
press
ZERO
and jump to
step 15.
12) Load the scale with the next
test weight. The display
offers the reading that will
occur without adjusting the
value. If the weight value
shown is acceptable push
TARE
and skip to step 14.
If the calibrated value needs
adjusting, go to step 13.
Test weights can be any in-capacity
weight, the order is not important.
The 4260 supports 5-Point Cal, Zero
and up to 4 span points.
13) Press the
USER
key to
scroll the number and
the
TARE
key to enter
each digit of the
calibration weight value.
When the entire calibration
weight is displayed, push
TARE
a second time to
finalize the calibration span
point. If the resultant cal
value is within limits, the
display will read “PASS”
briefly.
Example Value only.
/RDG
To set Next
Span Point
To skip additional
Span Points
To scroll the digit
To Enter the digit
into the cal weight
value
To complete the cal
weigh value entry
3DVV
USER
F
You can cancel calibration by
pressing Power and the scale
will reset to the previous
calibration constants.
USER
F
USER
F
TARE
T
ZERO
O
sto
TARE
T
USER
F
TARE
T
USER
F
TARE
T
USER
F
TARE
T
TARE
T
TARE
T
USER
F
TARE
T
TARE
T
32
MSI-4260 Port-A-Weigh Operator’s Manual
Figure 5-2. Standard Calibration Procedure (continued)