RF Remote Control Option
43
6.3 Setting the Transmitter Address
MODE_IN
window
CREATE
button
The MSI RF Remote Control Transmitter
allows the selection of one of 16,777,216
(2
24
) unique addresses. All transmitters
are supplied set to the same address. To
avoid contention with other units or to
create unique relationships, the address
should be changed. This is accomplished
by using a paper clip or probe to press the
CREATE button on the board through the
hole in the back of the case.
1. Press the button and a LED will light
up in the MODE_IND window,
indicating that the address is being
c r e a t e d . T h e a d d r e s s w i l l b e
randomized for as long as the button
is held down.
2. Release the button and the
randomized address will be saved
and the LED will begin flashing to
indicate that the Control Permissions may now be set.
3. Press all the buttons one by one that the transmitter will have the authority to
access. Press the CREATE button with the paper clip again or wait 17 seconds
for it to time out. The address and Control Permissions are now set.
6.4 Setting the Receiver Address
Once the transmitter is setup, you must now program the corresponding
MSI-4260
to
match. The steps are:
1. Program the
USER
key to “LEARN” (See Section 4.2). You can also remove
the battery from the
MSI-4260
. Then the “LEARN” mode will start when the
battery is plugged back in.
2. Start LEARN by pressing the
USER
key on the 4260 front panel (or plug in the
MSI-4260
battery).
3. Press each key on the Transmitter that you plan to use. During the “LEARN”
process the ACK annunciator will blink. You must complete all button pushes
before it times out in 17 seconds.
Any
MSI-4260
can learn up to 7 different remotes. However, never program multiple
MSI-4260
s to the same remote since they will all respond at the same time if they are
in range.
6.4.1
Resetting the 4260 RF Remote Receiver
1. Program the Func1 USER key to be Learn.
1. Press
USER
.
1. Press
ZERO
.
1. Reprogram the
MSI-4260
using the “Setting the Receiver Address” procedure.