
FIREHAWK M7 TELEMETRY MODULE
find the assigned base station within 20 seconds, it will
search for the first available base station and log on to it.
If a base station ID has not been assigned to the air mask,
it will log on to the first base station that it finds once the
unit has been turned on. Once a base station ID tag has
been scanned into the FireHawk M7 Control Module, this
base station ID will remain with the air mask until another
base station ID tag has been scanned.
The ID Tag has a space for the user to place a label in
which the ID information can be written on the outside of
the ID Tag for easy identification.
Before using the ID tag, inspect for damage or cracks in
the case. If damage is found, discard and replace the ID
tag.
Scanning the ID Tag into the FireHawk M7 Control
Module
1. Prior to pressurization of the air mask and during
inspection, the user can “tag in” to the air mask. The
most recent ID Tag data that is stored in the FireHawk
M7 Control Module will be used as the identification
for the air mask on the MSA Accountability System
Software. If no ID Tag data has been assigned to the
air mask, the FireHawk M7 Control Module serial num-
ber will be used as its identification on the base sta-
tion PC screen.
NOTE:
The air mask must
not be pressurized and
FireHawk M7 Control
Module must be turned off
to scan the ID Tag.
2. Take the ID Tag and
place the attachment
clip between your fin-
gers on your left hand.
The ID Tag should lie in your palm.
3. Move the FireHawk M7
Control Module over
top of the ID Tag.
4. Press and hold the
green mode button with
the thumb for 2 second
for the word “TAG” to
disply.
5. At that point, the word
will change to “OK”
within a few seconds
confirming the tagging
process is complete.
DO NOT use the tag to press the mode button, place it
on top of the FireHawk M7 Control Module, or next to
the FireHawk M7 Control Module. The tagging instruc-
tions must be followed to have the ID Tag within range
of the short range radio to complete the tagging
process. If the tag is not, the PASS device can lockup
showing the word “TAG” or “DATA” and cannot be
shutoff. To fix the lockup, the batteries must be
removed for 10 seconds and then reinstalled. Misuse
can result in serious injury or death.
6. The word “TAG” will display for 10 seconds if the
mode button is not pressed again. If the mode button
is pressed again after the word “TAG” appears, then
the PASS will enter data mode showing the word
“DATA”. To get back into tag mode, press the mode
button again to enter sleep mode and repeat the pre-
vious steps.
NOTE:
The “data” mode is used to change the device
settings or read the data log while using the FireHawk M7
Interface Software.
54
TAL 1705 (L) Rev. 18 - 10082858
Содержание FireHawk M7
Страница 8: ...NOTES 8 TAL 1705 L Rev 18 10082858...
Страница 14: ...NOTES 14 TAL 1705 L Rev 18 10082858...
Страница 20: ...NOTES 20 TAL 1705 L Rev 18 10082858...
Страница 30: ...NOTES 30 TAL 1705 L Rev 18 10082858...
Страница 32: ...NOTES 32 TAL 1705 L Rev 18 10082858...
Страница 40: ...NOTES 40 TAL 1705 L Rev 18 10082858...
Страница 42: ...NOTES 42 TAL 1705 L Rev 18 10082858...
Страница 44: ...NOTES 44 TAL 1705 L Rev 18 10082858...
Страница 48: ...NOTES 48 TAL 1705 L Rev 18 10082858...
Страница 56: ......