USING THE AIR MASK
25
TAL 1705 (L) Rev. 18 - 10082858
ACTION
VISIBLE/AUDIBLE INDICATOR
VISIBLE INDICATOR,
without Thermal Alarm
with Thermal Alarm
CONTROL MODULE
automatic activation with
the system pressurized
manual activation
sensing mode (with or
without pressure
pre-alarm with
or without
pressure
full alarm (with or without
pressure)
deactivation
of full alarm
deactivation of pre-alarm
(with shake or move unit)
low battery
thermal alarm activation
(see thermal alarm activa-
tion curve)
radio link with
base station*
evacuation signal received*
redundant alarm (cylinder
pressure is below 25% of
rated service pressure
single rising tone with bee-
bop
start-up single rising tone
with bee-bop (also full
alarm)
none
low volume, low urgency
medium volume,
medium urgency
high volume, high urgency
full volume, high urgency
with a buzz
Bee
none
1 beep every 5 seconds
N/A
none
none
continuous beep beep
none
single rising tone with bee-
bop
start-up single rising tone
with bee-bop (also full
alarm)
none
low volume, low urgency
medium volume,
medium urgency
high volume, high urgency
full volume high urgency
with a buzz
Bee
none
1 beep every 5 seconds
1 beep every 3 seconds
none
none
continuous beep beep
none
green/red LED flash front
panel
green/red LED flash front
panel - red light flashing
green LED flashed
red LED flashes
red LED flashes
red LED flashes
green LED flashes
green LED flashes
empty battery icon on dis-
play
flashing thermometer icon
on display
radio link indicator icon in
upper left corner of display
radio link indicator icon dis-
appears
flashing “running man” icon
appears on display
red LED flashes
first 4 sec-
onds
(approx.)
second 4
seconds
(approx.)
last 4 sec-
onds
(approx.)
first push
of reset
button
second
push of
reset button
link is
established
out of
range
*Action only available when the FireHawk M7 Telemetry Module is used.
Chart 3: Audible/Visible Indicators, FireHawk M7 Power Module (integrated PASS version)
metal plate on the front edge of the bracket.
2. Rotate the FireHawk M7 HUD so that the tab falls into
the slot behind the thumbscrew.
3. Thread the thumbscrew into the tab to finger-tight.
DO NOT use a screwdriver to tighten the thumbscrew.
Содержание FireHawk M7
Страница 8: ...NOTES 8 TAL 1705 L Rev 18 10082858...
Страница 14: ...NOTES 14 TAL 1705 L Rev 18 10082858...
Страница 20: ...NOTES 20 TAL 1705 L Rev 18 10082858...
Страница 30: ...NOTES 30 TAL 1705 L Rev 18 10082858...
Страница 32: ...NOTES 32 TAL 1705 L Rev 18 10082858...
Страница 40: ...NOTES 40 TAL 1705 L Rev 18 10082858...
Страница 42: ...NOTES 42 TAL 1705 L Rev 18 10082858...
Страница 44: ...NOTES 44 TAL 1705 L Rev 18 10082858...
Страница 48: ...NOTES 48 TAL 1705 L Rev 18 10082858...
Страница 56: ......