COLD WEATHER OPERATION
Suggested Procedures for Cold Weather Operation
Moisture can cause problems in the air mask if it freezes.
However, moisture can cause freezing problems even if
the surrounding air is above freezing. Air flowing from the
cylinder through the first and second stage regulators
drops from cylinder pressure to close to atmospheric
pressure very quickly. This causes the air to expand and
creates a cooling effect. Although the surrounding tem-
perature may be warmer than 32°F, the temperature inside
the regulator may be lower. Any water inside could turn to
ice and restrict airflow.
Prior to storage of the air mask at temperatures below 0˚F,
verify that the FireHawk M7 Power Module, FireHawk M7
HUD, and FireHawk M7 I-HUD are equipped with full
charge batteries. Verify that the FireHawk M7 HUD and
FireHawk M7 I-HUD do not display low battery status
indicators.
1. To keep moisture from entering the mask mounted
regulator, keep the Firehawk Regulator in the belt
mounted regulator holder when not in use.
2. When the air mask is away from heat, water spray can
freeze on the Firehawk Regulator surface. Ice can
build up and bind the side buttons or the bypass
valve. Before entering or re-entering a hazardous
atmosphere, ensure the side buttons and bypass valve
are ice-free and operating properly. Periodically check
the bypass to be sure it is ice-free.
3. Moisture can enter through the cylinder valve or cou-
pling nut when cylinders are replaced on the air mask.
When replacing cylinders, ensure moisture or contami-
nation does not enter the system. Remove any ice
from these fittings. Wipe the coupling nut threads and
cylinder valve threads before installing a new cylinder.
Water can contaminate the system and freeze.
4. When cleaning the air mask, ensure water does not
enter the facepiece or Firehawk Regulator.
5. Thoroughly dry the facepiece and mask mounted reg-
ulator after cleaning and disinfecting. Follow
Confidence Plus® Cleaning Solution instructions.
NOTE:
Fresh batteries must be installed in the FireHawk
M7 HUD or I-HUD, FireHawk M7 Power Module, and
NightFighter HUD Transmitter prior to storage of the Air
Mask at cold temperature for an extended period of time.
31
TAL 1705 (L) Rev. 18 - 10082858
Содержание FireHawk M7
Страница 8: ...NOTES 8 TAL 1705 L Rev 18 10082858...
Страница 14: ...NOTES 14 TAL 1705 L Rev 18 10082858...
Страница 20: ...NOTES 20 TAL 1705 L Rev 18 10082858...
Страница 30: ...NOTES 30 TAL 1705 L Rev 18 10082858...
Страница 32: ...NOTES 32 TAL 1705 L Rev 18 10082858...
Страница 40: ...NOTES 40 TAL 1705 L Rev 18 10082858...
Страница 42: ...NOTES 42 TAL 1705 L Rev 18 10082858...
Страница 44: ...NOTES 44 TAL 1705 L Rev 18 10082858...
Страница 48: ...NOTES 48 TAL 1705 L Rev 18 10082858...
Страница 56: ......