REMOVING THE AIR MASK
DISCONNECTING THE SLIDE-TO-CONNECT
FIREHAWK REGULATOR
1. Grasp the top of the
regulator.
2. Push the side release
buttons and pull the
regulator down and out
of facepiece.
NOTE:
The regulator can hang on cover rail in a stand-by
mode.
3. Slide the regulator up
the cover rail until the
regulator slide button is
free of the cover rail.
4. Close the cylinder
valve fully. Open the
Firehawk Regulator
bypass to release sys-
tem pressure. Close
the bypass.
5. When the pressure falls below 200 psi, turn the
FireHawk M7 Control Module (integrated PASS ver-
sion) off by pressing the reset button (yellow) two
times within approximately one second.
NOTE:
FireHawk M7 HUD or I-HUD will automatically turn
itself OFF, approximately 60 seconds after the air mask
has been depressurized. (The red LED will flash until the
FireHawk M7 HUD or I-HUD turns off)
6. Stow the Firehawk Regulator, oriented with the slide
button facing down in the belt mounted holder when it
is not in use.
7. To remove the facepiece, fully loosen the harness
straps and pull the facepiece up and away from the
face.
8. To remove the carrier and harness, press the waist
belt buckle release button IN.
9. Disconnect the chest strap buckle (if used).
10. To loosen the shoulder straps, grasp the pull tabs and
push them out and away from the body.
11. Slip the right arm out of the shoulder strap first, and
then remove the harness.
NOTE:
Be sure to replace the cylinder with a fully charged
one. Complete Inspection and Cleaning and Disinfecting
Procedures outlined in this manual. Ensure that the com-
plete SCBA is clean and dry. Ensure that facepiece head
harness straps and harness adjustment straps are fully
extended. Place the complete air mask in the storage
case or suitable storage location so that it can be easily
reached for emergency use. (See storage instructions.)
DISCONNECTING THE FIREHAWK
PUSH-TO-CONNECT REGULATOR
1. Grasp the top of the regulator.
2. Push the side release buttons and pull the regulator
out of facepiece.
3. Close the cylinder valve fully. Open the Firehawk
Regulator bypass to release system pressure. Close
the bypass.
4. When the pressure falls below 200 psi, turn the
FireHawk M7 Control Module (integrated PASS ver-
sion) off by depressing the reset button (yellow) two
times within approximately one second.
NOTE:
The FireHawk M7 HUD or I-HUD will automatically
turn itself OFF, approximately 60 seconds after the air
mask has been depressurized. (A red LED will flash until
the FireHawk M7 HUD or I-HUD turns off)
5. Stow the Firehawk Regulator in the belt mounted
holder when it is not in use.
6. To remove the facepiece, fully loosen the harness
straps and pull the facepiece up and away from the
face.
7. To remove the carrier and harness, press the waist
36
TAL 1705 (L) Rev. 18 - 10082858
Содержание FireHawk M7
Страница 8: ...NOTES 8 TAL 1705 L Rev 18 10082858...
Страница 14: ...NOTES 14 TAL 1705 L Rev 18 10082858...
Страница 20: ...NOTES 20 TAL 1705 L Rev 18 10082858...
Страница 30: ...NOTES 30 TAL 1705 L Rev 18 10082858...
Страница 32: ...NOTES 32 TAL 1705 L Rev 18 10082858...
Страница 40: ...NOTES 40 TAL 1705 L Rev 18 10082858...
Страница 42: ...NOTES 42 TAL 1705 L Rev 18 10082858...
Страница 44: ...NOTES 44 TAL 1705 L Rev 18 10082858...
Страница 48: ...NOTES 48 TAL 1705 L Rev 18 10082858...
Страница 56: ......