QUICK-FILL SYSTEM
air is leaking:
a. Immediately reconnect the quick-fill hose to seal off
the leak and return to fresh air.
b. If the hose will not reconnect, reach behind and
close the cylinder valve. Air pressure in the regulator
will drop, and the leak will slow down.
c. Quickly replace the protective dust cap on the male
fitting. This will form a redundant seal.
d. Open the cylinder valve and return to fresh air
immediately. The dust cover prevents dirt, water,
and debris from entering the fitting, and acts as a
redundant seal.
QUICK-FILL SYSTEM HOSE STORAGE
1. Preparing the Quick-Fill System hose for storage:
a. Press in on the center of the quick-disconnect dust
cap to release any pressure in the quick-fill hose.
b. Roll up the hose and place it in its protective pouch.