DONNING
3. Open the cylinder valve
fully.
INSTALLING PUSH-TO-CONNECT MASK MOUNTED
REGULATOR
1. Grasp regulator and
orient regulator so that
red bypass knob is
pointing to the right.
2. Insert regulator into
facepiece adapter by
pushing inward.
3. Ensure the regulator locks into the facepiece.
4. Check proper engagement by pulling on the regulator
to ensure regulator is securely attached to facepiece.
Do not use the respirator unless the regulator is con-
nected properly. A regulator that is not installed cor-
rectly can separate from the facepiece unexpectedly.
Return the respirator to an MSA trained or certified
repairperson to correct the condition. Failure to follow
this warning can result in serious personal injury or
death.
5. Inhale sharply to start the airflow.
a. Check the bypass again by turning the red knob
counter-clockwise until you feel increased airflow.
Close the bypass.
There must be a continuous flow of air when the
bypass knob is opened. If not, do not use the appara-
tus. The respirator must be checked and the condition
corrected by an MSA trained or certified repairperson
before using it. Failure to follow this warning can
result in serious personal injury or death.
Note:
If the Air Mask passes all tests, the unit is ready to
use. Remember, you must perform these tests every time
before you enter the hazardous atmosphere. If the unit
fails to meet any of the tests, the condition(s) must be
corrected before using the apparatus.
INSTALLING SLIDE MASK MOUNTED REGULATOR
1. Grasp regulator and orient regulator so that red
bypass knob is pointing to the right and slide button is
on top.
2. Slide regulator onto rail (fast track) of facepiece cover.
Slide regulator down the rail cover until regulator
stops.
3. Insert regulator into facepiece adapter by pushing
inward.
4. Ensure the regulator locks into facepiece.
5. Check proper engagement by pulling on the regulator
to ensure regulator is securely attached to facepiece.
Do not use the respirator unless the regulator is con-
nected properly. A regulator that is not installed cor-
rectly can separate from the facepiece unexpectedly.
Return the respirator to an MSA trained or certified
repairperson to correct the condition. Failure to follow
this warning can result in serious personal injury or
death.
6. Inhale sharply to start the airflow.
a. Check the bypass again by turning the red knob
counter-clockwise until you feel increased airflow.
Close the bypass.
There must be a continuous flow of air when the
bypass knob is opened. If not, do not use the appara-
tus. The respirator must be checked and the condition
corrected by an MSA trained or certified repairperson
before using it. Failure to follow this precaution may
result in serious personal injury or death.
Note:
If the Air Mask passes all tests, the unit is ready to
use. Remember, you must perform these tests every time
before you enter the hazardous atmosphere. If the unit
fails to meet any of the tests, the condition(s) must be
corrected before using the apparatus.
9
TAL 5010 (L) Rev. 3 - 10037469
WARNING
WARNING
WARNING
WARNING
Содержание AirHawk MMR
Страница 4: ...NOTES 4 TAL 5010 L Rev 3 10037469...
Страница 14: ...NOTES 14 TAL 5010 L Rev 3 10037469...
Страница 16: ...NOTES 16 TAL 5010 L Rev 3 10037469...
Страница 18: ...NOTES 18 TAL 5010 L Rev 3 10037469...
Страница 21: ...NOTES 21 TAL 5010 L Rev 3 10037469...
Страница 22: ...NOTES 22 TAL 5010 L Rev 3 10037469...
Страница 24: ......