MSA AirHawk MMR Скачать руководство пользователя страница 5

DESCRIPTION

DESCRIPTION

The Air Masks from MSA are pressure-demand, self-con-
tained breathing apparatus (SCBA) certified by the
National Institute for Occupational Safety and Health
(NIOSH) for use in atmospheres immediately dangerous to
life or health:

``Immediately dangerous to life or health’’ means condi-
tions that pose an immediate threat to life or health or
conditions that pose an immediate threat of severe expo-
sure to contaminants, such as radioactive materials,
which are likely to have adverse cumulative or delayed
effects on health’’ [Title 42 CFR, Part 84.2, (Q)]

This SCBA is not compliant with National Fire
Protection Association (NFPA) Standard 1981. The
SCBA should not be used for firefighting applica-
tions where NFPA compliance is required.

This SCBA is not NIOSH approved for use against
CBRN live agents. If NIOSH CBRN Agent Approval
is required, use a NIOSH CBRN Agent approved
Firehawk Air Mask.

This SCBA must be equipped with an Ultra Elite
Hycar facepiece (model numbers 7-935-7. 7-935-8,
and 7-935-9) and a CBRN regulator (model num-
bers 10060982 or 10060983) when exposure to
CBRN live agents is possible. Do NOT use a sili-
cone facepiece or a regulator that is not identified
as CBRN regulator against CBRN live agents.

Failure to follow these warnings can result in serious
personal injury or death.

AirHawk MMR breathing apparatus consists of the follow-
ing major sub-assemblies.

first stage regulator

second stage regulator

air cylinder and valve

whistle audible alarm

carrier and harness

facepiece

FIRST STAGE REGULATOR

The first stage regulator is a "balanced-type’’ pressure
reducer that keeps the pressure to the mask mounted
regulator at approximately 80 psig throughout the entire
operating pressure range of the cylinder. The regulator has
a redundancy feature to minimize the possibility of a first
stage failure. The regulator uses a large sintered filter
which is easy to replace. The filter captures particulates
that may be in the air stream.

SECOND STAGE REGULATOR

This is a pressure-demand regulator, which keeps a posi-
tive pressure in the facepiece all the time. The release
button on top of the regulator stops air flow. To stop air-
flow, push the button in. To restart the regulator, inhale
sharply. The regulator attaches to the facepiece with a
Push-To-Connect connector or slide connector. The regu-
lator delivers large flow rates accurately and quickly.

Airhawk SCBA with the Firehawk MMR (model numbers
10060982and 10060983) are considered by MSA to be
“CBRN hardened.” They can be identified by Firehawk
Regulator model number and the CBRN marking on the
underside of the regulator housing. SCBA with these reg-
ulator models have passed CBRN live agent testing, but
are not CBRN-approved by NIOSH since they are not cer-
tified as NFPA compliant.

AIR CYLINDER AND VALVE

*as approved by NIOSH

The air cylinder and valve consists of a tank and a cylin-
der valve assembly. The cylinder valve includes a valve
body, cylinder valve inlet tube, handwheel, safety disc
(burst disc), and pressure gauge. The pressure gauge
shows the air pressure in the cylinder continuously. The
gauge is calibrated in 100 psig increments. For example,
a gauge reading of 20 is read as 20 x 100 or 2,000 psig. A
handwheel is used to open and close the cylinder valve.

WHISTLE AUDIBLE ALARM

The whistle audible alarm sounds when there is approxi-
mately 25% of the SCBA’s rated service time remaining.
The whistle also sounds when the cylinder valve is first
opened, providing an audible indication that the alarm is
functioning.

5

TAL 5010 (L) Rev. 3 - 10037469 

Capacity

Pressure

Rated Svc*

Cubic Ft.

psig

Life (Min.)

45

2216

30

45

4500

30

66

4500

45

88

4500

60

Approx. Remaining

Cylinder

Service Time

30-min. 2216 psig

7 min.

30-min. 4500 psig

7 min.

45-min. 4500 psig

11 min.

60-min. 4500 psig

14 min.

Содержание AirHawk MMR

Страница 1: ...ONS inside For any additional information relative to use or repair write or call 1 800 MSA 2222 during regular working hours See separate insert for NIOSH approval information P N 10039170 For air li...

Страница 2: ...e furnished by the manufacturer under the pertinent approval shall be maintained NIOSH Approval Information is included as a supplement to these instructions P N 10039170 IMPORTANT NOTICE FOR RESPIRAT...

Страница 3: ...safe non haz ardous non toxic atmosphere 5 Return to a safe atmosphere immediately if discol oration crazing blistering cracking or other dete rioration of the lens material is observed 6 Users must w...

Страница 4: ...NOTES 4 TAL 5010 L Rev 3 10037469...

Страница 5: ...nimize the possibility of a first stage failure The regulator uses a large sintered filter which is easy to replace The filter captures particulates that may be in the air stream SECOND STAGE REGULATO...

Страница 6: ...n evenly distributes cylinder weight across the wearer s hips FACEPIECE The facepiece is available in three sizes Only Ultra Elite Hycar facepieces model numbers 7 935 7 7 935 8 and 7 935 9 have been...

Страница 7: ...AND WHISTLE AUDIBLE ALARM CHECKS TESTING 1 Grasp the mask mounted regulator and push the top release button 2 Check that the red bypass knob is fully closed clockwise 3 Reach behind and open the cyli...

Страница 8: ...straps first by pulling them straight back not out Tighten the temple straps the same way Tuck in the ends of the straps so that they lay flat across the head 4 Push headband pad towards neck retighte...

Страница 9: ...ore using the apparatus INSTALLING SLIDE MASK MOUNTED REGULATOR 1 Grasp regulator and orient regulator so that red bypass knob is pointing to the right and slide button is on top 2 Slide regulator ont...

Страница 10: ...return to fresh air The whistle activates when cylinder pressure drops below approximate values 550 psig approximately for low pressure 1125 psig approximately for high pressure when the whistle acti...

Страница 11: ...and pull regulator down and out of facepiece adapter Note Regulator can hang on cover rail in a stand by mode 3 Slide regulator up rail until regulator slide button is free of cover rail 4 Close the c...

Страница 12: ...burst disc and gasket are installed prior to cylinder recharging Establish the service pressure of the cylinder Type 3AA steel cylin ders that bear a plus sign after the latest retest date may be rech...

Страница 13: ...Ice can build up and freeze the buttons bypass valve and the release tabs Before entering or re entering a hazardous atmos phere make sure the buttons release tabs and bypass valve are ice free and op...

Страница 14: ...NOTES 14 TAL 5010 L Rev 3 10037469...

Страница 15: ...e c Rinse the facepiece and components in clean warm 110 F water preferably running and drained d Clean the pressure demand exhalation valve by pressing in on the stem with a blunt object and flushing...

Страница 16: ...NOTES 16 TAL 5010 L Rev 3 10037469...

Страница 17: ...hat the required inspections and tests be performed on all SCBA cylinders in accordance with Department of Transportation DOT regulations DOT reg ulations require that composite cylinders be retired f...

Страница 18: ...NOTES 18 TAL 5010 L Rev 3 10037469...

Страница 19: ...e audible warn ing device be checked by observing the regulator gauge pressure at which the alarms sounds Perform this test with a minimum cylinder pressure of 1 200 psig for the Low Pressure Air Mask...

Страница 20: ...ly and Repair sections and includes installation of the Regulator overhaul kits MSA breathing apparatus must be flow tested every year using an MSA approved flow test device The following table summar...

Страница 21: ...NOTES 21 TAL 5010 L Rev 3 10037469...

Страница 22: ...NOTES 22 TAL 5010 L Rev 3 10037469...

Страница 23: ...parts that after by MSA are proven to be d f defective and or will provided at no cost t F Purchaser s of re to repair not cause the remedy established hereby to fail of its essential purpose MSA r e...

Страница 24: ......

Отзывы: