MSA AirHawk MMR Скачать руководство пользователя страница 2

INTRODUCTION

NIOSH APPROVAL INFORMATION CAUTIONS AND
LIMITATIONS

D-  Air-line respirators can be used only when the respira-

tors are supplied with respirable air meeting the
requirements of CGA G-7-1 Grade D or higher quality.

E-  Use on the pressure gauges and hose lengths speci-

fied in the User’s Instructions.

I-  Contains electrical parts which have not been evaluat-

ed as an ignition source in flammable or explosive
atmospheres by MSHA/NIOSH.

J-  Failure to properly use and maintain this product could

result in injury or death.

M-  All approved respirators shall be selected, fitted, used

and maintained in accordance with MSHA, OSHA and
other applicable regulations.

N-  Never substitute, modify, add or omit parts. Use only

exact replacement parts in the configuration as speci-
fied by the manufacturer.

O-  Refer to Users Instructions, and/or maintenance man-

uals for information on use and maintenance of these
respirators.

S-  Special or critical Users Instructions and/or specific

use limitations apply. Refer to user instructions before
donning.

S - SPECIAL OR CRITICAL USERS INSTRUCTIONS

Approved for use at temperatures above -25°F. Approved
only when the compressed-air container is fully charged
with air meeting the requirements of the Compressed Gas
Association Specification G-7 for quality verification level
(grade) D air or equivalent specifications. The cylinder
shall meet applicable DOT specifications.

Use with adequate skin protection when worn in gases
and vapors that poison by skin absorption (for example:
hydrocyanic-acid gas).

In making renewals or repairs, parts identical with those
furnished by the manufacturer under the pertinent
approval shall be maintained.

NIOSH Approval Information is included as a supplement
to these instructions (P/N 10039170).

IMPORTANT NOTICE FOR RESPIRATORY PROTEC-
TION PROGRAM ADMINISTRATORS

1.  An adequate respiratory protection program must

include knowledge of hazards, hazard assessment,
selection of proper respiratory protective equipment,
instruction and training in the use of equipment,
inspection and maintenance of equipment, and med-
ical surveillance. [See OSHA regulations, Title 29 CFR,
Part 1910. 134, Subpart I, Par. 1910. 134 (c).]

2.  This SCBA may be used only after proper instruction

and training in its use as specified in NFPA-1500 and
OSHA regulations Title 29 CFR, Part 1910. 134,
Subpart 1, Par. 1910. 134 (b) (3).

3.  This SCBA must be secured by a positive mechanical

means if stowed within an enclosed seating area of
fire department vehicles, or in a compartment with a
positive latching door. The method of holding the
SCBA in place must be designed to minimize injury to
persons in the vehicle in the event of accident, rapid
deceleration, or acceleration.

4.  Do not mark the SCBA, i.e., with stamps, labels, paint

or other method. Use of such markings may interfere
with apparatus use or may constitute a flammability
hazard.

5.  Be sure that no other equipment interferes with the

SCBA facial seal, or with the users hands, or other
necessary means of mobility.

For more information on self-contained breathing appara-
tus use and performance standards, please consult the
following publications:

2

TAL 5010 (L) Rev. 3 - 10037469 

TABLE OF CONTENTS

Introduction .............................................................................................................................................................................2
Description ..............................................................................................................................................................................5
Donning ...................................................................................................................................................................................7
Removing the Apparatus ......................................................................................................................................................11
Cold Weather Operation .......................................................................................................................................................13
Cleaning/Disinfecting ............................................................................................................................................................15
Inspections............................................................................................................................................................................17
Functional Tests ....................................................................................................................................................................19
Flow Test/Overhaul Requirements ........................................................................................................................................20
Lifetime Warranty ..................................................................................................................................................................23

Содержание AirHawk MMR

Страница 1: ...ONS inside For any additional information relative to use or repair write or call 1 800 MSA 2222 during regular working hours See separate insert for NIOSH approval information P N 10039170 For air li...

Страница 2: ...e furnished by the manufacturer under the pertinent approval shall be maintained NIOSH Approval Information is included as a supplement to these instructions P N 10039170 IMPORTANT NOTICE FOR RESPIRAT...

Страница 3: ...safe non haz ardous non toxic atmosphere 5 Return to a safe atmosphere immediately if discol oration crazing blistering cracking or other dete rioration of the lens material is observed 6 Users must w...

Страница 4: ...NOTES 4 TAL 5010 L Rev 3 10037469...

Страница 5: ...nimize the possibility of a first stage failure The regulator uses a large sintered filter which is easy to replace The filter captures particulates that may be in the air stream SECOND STAGE REGULATO...

Страница 6: ...n evenly distributes cylinder weight across the wearer s hips FACEPIECE The facepiece is available in three sizes Only Ultra Elite Hycar facepieces model numbers 7 935 7 7 935 8 and 7 935 9 have been...

Страница 7: ...AND WHISTLE AUDIBLE ALARM CHECKS TESTING 1 Grasp the mask mounted regulator and push the top release button 2 Check that the red bypass knob is fully closed clockwise 3 Reach behind and open the cyli...

Страница 8: ...straps first by pulling them straight back not out Tighten the temple straps the same way Tuck in the ends of the straps so that they lay flat across the head 4 Push headband pad towards neck retighte...

Страница 9: ...ore using the apparatus INSTALLING SLIDE MASK MOUNTED REGULATOR 1 Grasp regulator and orient regulator so that red bypass knob is pointing to the right and slide button is on top 2 Slide regulator ont...

Страница 10: ...return to fresh air The whistle activates when cylinder pressure drops below approximate values 550 psig approximately for low pressure 1125 psig approximately for high pressure when the whistle acti...

Страница 11: ...and pull regulator down and out of facepiece adapter Note Regulator can hang on cover rail in a stand by mode 3 Slide regulator up rail until regulator slide button is free of cover rail 4 Close the c...

Страница 12: ...burst disc and gasket are installed prior to cylinder recharging Establish the service pressure of the cylinder Type 3AA steel cylin ders that bear a plus sign after the latest retest date may be rech...

Страница 13: ...Ice can build up and freeze the buttons bypass valve and the release tabs Before entering or re entering a hazardous atmos phere make sure the buttons release tabs and bypass valve are ice free and op...

Страница 14: ...NOTES 14 TAL 5010 L Rev 3 10037469...

Страница 15: ...e c Rinse the facepiece and components in clean warm 110 F water preferably running and drained d Clean the pressure demand exhalation valve by pressing in on the stem with a blunt object and flushing...

Страница 16: ...NOTES 16 TAL 5010 L Rev 3 10037469...

Страница 17: ...hat the required inspections and tests be performed on all SCBA cylinders in accordance with Department of Transportation DOT regulations DOT reg ulations require that composite cylinders be retired f...

Страница 18: ...NOTES 18 TAL 5010 L Rev 3 10037469...

Страница 19: ...e audible warn ing device be checked by observing the regulator gauge pressure at which the alarms sounds Perform this test with a minimum cylinder pressure of 1 200 psig for the Low Pressure Air Mask...

Страница 20: ...ly and Repair sections and includes installation of the Regulator overhaul kits MSA breathing apparatus must be flow tested every year using an MSA approved flow test device The following table summar...

Страница 21: ...NOTES 21 TAL 5010 L Rev 3 10037469...

Страница 22: ...NOTES 22 TAL 5010 L Rev 3 10037469...

Страница 23: ...parts that after by MSA are proven to be d f defective and or will provided at no cost t F Purchaser s of re to repair not cause the remedy established hereby to fail of its essential purpose MSA r e...

Страница 24: ......