DONNING

8.  Check for air leaks. Open cylinder valve fully to pres-

surize system, then close the cylinder valve and watch
the harness pressure gauge.

9.  If the needle drops more than 100 psi in 10 seconds,

there is a leak. Do not use the apparatus until the leak
is found and corrected.

10. Crack the bypass valve slowly to bleed off pressure

until gauge needle drops below:

550 psig - approximately (low-pressure system) or,
1125 psig – approximately (high-pressure system) 

The whistle will sound. The whistle must continue to
sound until pressure is less than 200 psig. Close the
bypass fully.

If the whistle fails to sound, do not use the apparatus.
The SCBA must be checked and corrected for proper
operation by an MSA trained or certified repairperson
before using. Failure to follow this warning may result
serious personal injury or death.

Note: 

Before donning, check that the regulator sealing

ring is seated properly in its groove, and that it is not torn,
gouged, or nicked.

DONNING THE FACEPIECE

Do not wear eye glasses under the facepiece. The
temples or sidebars on eye glasses will prevent an air-
tight seal. if you must wear glasses, install the specta-
cle kit. Failure to follow this precaution may cause
inhalation of contaminated air, resulting in serious res-
piratory injury or death.

1.  Extend the facepiece straps fully. Place neckstrap

around your neck and don the facepiece by inserting
your chin first.

2.  Pull the head harness

completely over your
head and tighten the
lower (neck) straps.

3.  Tighten the lower (neck) harness straps first, by pulling

them straight back, not out. Tighten the temple straps
the same way. Tuck in the ends of the straps so that
they lay flat across the head.

4.  Push headband pad towards neck, retighten the

straps (if necessary) for best visibility and fit. Tuck in
the ends of the straps so they lie flat across the head.

FACEPIECE FIT CHECK

Check the inhalation valve, inhale. If you do not
receive sufficient flow of air, do not use facepiece. The
facepiece must be repaired or replaced.

1.  To check for facepiece

fit, hold the palm of
your hand over the inlet
connection and inhale.
Hold your breath at
least 10 seconds. The
facepiece should col-
lapse and stay col-
lapsed against your
face. If it does not,
readjust the facepiece
and test again. 

If this

does not correct the leak, do not use the face-
piece.

2.  Test the exhalation

valve, take a deep
breath and hold it.
Block the inlet connec-
tion with the palm of
your hand and exhale.
If the exhalation valve
is stuck, you may feel a
heavy rush of air
around the facepiece.

Note:

You may need to exhale sharply to open the valve.

If this does not release the valve, do not use the face-
piece.

This device may not seal properly with your face if you
have a beard, gross sideburns or similar physical
characteristics (see ANSI Z88.2). An improper facial
seal may allow contaminants to leak into the face-
piece, reducing or eliminating respiratory protection.
Do not use this device if such conditions exist. The
face-to-facepiece seal must be tested before each
use. Never remove the facepiece except in a safe,
non-hazardous non-toxic atmosphere. Failure to fol-
low this warning can result in serious personal injury
or death.

8

TAL 5010 (L) Rev. 3 - 10037469 

WARNING

WARNING

WARNING

WARNING

Содержание AirHawk MMR

Страница 1: ...ONS inside For any additional information relative to use or repair write or call 1 800 MSA 2222 during regular working hours See separate insert for NIOSH approval information P N 10039170 For air li...

Страница 2: ...e furnished by the manufacturer under the pertinent approval shall be maintained NIOSH Approval Information is included as a supplement to these instructions P N 10039170 IMPORTANT NOTICE FOR RESPIRAT...

Страница 3: ...safe non haz ardous non toxic atmosphere 5 Return to a safe atmosphere immediately if discol oration crazing blistering cracking or other dete rioration of the lens material is observed 6 Users must w...

Страница 4: ...NOTES 4 TAL 5010 L Rev 3 10037469...

Страница 5: ...nimize the possibility of a first stage failure The regulator uses a large sintered filter which is easy to replace The filter captures particulates that may be in the air stream SECOND STAGE REGULATO...

Страница 6: ...n evenly distributes cylinder weight across the wearer s hips FACEPIECE The facepiece is available in three sizes Only Ultra Elite Hycar facepieces model numbers 7 935 7 7 935 8 and 7 935 9 have been...

Страница 7: ...AND WHISTLE AUDIBLE ALARM CHECKS TESTING 1 Grasp the mask mounted regulator and push the top release button 2 Check that the red bypass knob is fully closed clockwise 3 Reach behind and open the cyli...

Страница 8: ...straps first by pulling them straight back not out Tighten the temple straps the same way Tuck in the ends of the straps so that they lay flat across the head 4 Push headband pad towards neck retighte...

Страница 9: ...ore using the apparatus INSTALLING SLIDE MASK MOUNTED REGULATOR 1 Grasp regulator and orient regulator so that red bypass knob is pointing to the right and slide button is on top 2 Slide regulator ont...

Страница 10: ...return to fresh air The whistle activates when cylinder pressure drops below approximate values 550 psig approximately for low pressure 1125 psig approximately for high pressure when the whistle acti...

Страница 11: ...and pull regulator down and out of facepiece adapter Note Regulator can hang on cover rail in a stand by mode 3 Slide regulator up rail until regulator slide button is free of cover rail 4 Close the c...

Страница 12: ...burst disc and gasket are installed prior to cylinder recharging Establish the service pressure of the cylinder Type 3AA steel cylin ders that bear a plus sign after the latest retest date may be rech...

Страница 13: ...Ice can build up and freeze the buttons bypass valve and the release tabs Before entering or re entering a hazardous atmos phere make sure the buttons release tabs and bypass valve are ice free and op...

Страница 14: ...NOTES 14 TAL 5010 L Rev 3 10037469...

Страница 15: ...e c Rinse the facepiece and components in clean warm 110 F water preferably running and drained d Clean the pressure demand exhalation valve by pressing in on the stem with a blunt object and flushing...

Страница 16: ...NOTES 16 TAL 5010 L Rev 3 10037469...

Страница 17: ...hat the required inspections and tests be performed on all SCBA cylinders in accordance with Department of Transportation DOT regulations DOT reg ulations require that composite cylinders be retired f...

Страница 18: ...NOTES 18 TAL 5010 L Rev 3 10037469...

Страница 19: ...e audible warn ing device be checked by observing the regulator gauge pressure at which the alarms sounds Perform this test with a minimum cylinder pressure of 1 200 psig for the Low Pressure Air Mask...

Страница 20: ...ly and Repair sections and includes installation of the Regulator overhaul kits MSA breathing apparatus must be flow tested every year using an MSA approved flow test device The following table summar...

Страница 21: ...NOTES 21 TAL 5010 L Rev 3 10037469...

Страница 22: ...NOTES 22 TAL 5010 L Rev 3 10037469...

Страница 23: ...parts that after by MSA are proven to be d f defective and or will provided at no cost t F Purchaser s of re to repair not cause the remedy established hereby to fail of its essential purpose MSA r e...

Страница 24: ......

Отзывы: