CLEANING AND DISINFECTING

CLEANING AND DISINFECTING

Depending on the cleaning policy adopted, either a desig-
nated person or the user should clean each device after
each use. ANSI standards suggest that users should be
trained in the cleaning procedure. Confidence Plus
Cleaning Solution (P/N 10009971) from MSA is recom-
mended. It cleans and disinfects in one operation. It
retains its germicidal efficiency in hard water to inhibit the
growth of bacteria. It will not deteriorate rubber, plastic,
glass, or metal parts. Refer to label for user instructions.

DO NOT use any cleaning substances that can or
might attack any part of the apparatus.

Alcohol should not be used as a germicide because it
may deteriorate rubber parts.

If not rinsed thoroughly, cleaning agent residue may
irritate the wearer’s skin.

1. Preparing 

Solution

a. Follow the instructions with the Confidence Plus

Cleaning Solution.

b. If the Confidence Plus Cleaning Solution is not

used, wash in a mild cleaning solution, rinse thor-
oughly, and submerge in a germicide solution for
the manufacturer’s recommended time.

2.  Clean and Disinfect the Facepiece

a. Remove the mask mounted regulator from the face-

piece.

b. Thoroughly wash the facepiece (and nosecup) in the

cleaning solution. A soft brush or sponge can be
used to clean the soiled facepiece.

c. Rinse the facepiece and components in clean,

warm (110°F), water (preferably running and
drained).

d. Clean the pressure demand exhalation valve by

pressing in on the stem with a blunt object and
flushing with clean water.

e. Allow the facepiece to air dry. Do not dry the parts

by placing them near a heater or in direct sunlight.
The rubber will deteriorate.

f. Operate the exhalation valve by hand to be sure it

works properly.

Note: 

Do not force-dry the parts by placing them in a

heater or in direct sunlight. The rubber will deteriorate.
When the facepiece is thoroughly dry, store the facepiece
in the plastic bag that it was shipped in.

3.  In general, only the facepiece requires cleaning and

disinfecting after each use. If the apparatus is soiled
(i.e. heavy smoke residue, or dirt accumulation) use a
sponge damp with mild soap solution or use a
soft/medium bristle brush to remove deposits that
may interfere with normal operation of:

a. Harness (straps and buckles)
b. Cylinder carrier
c. Cylinder (coupling nut, gauge, outlet connection)
d. Whistle audible alarm
e. MMR remote gauge lens
f. First stage regulator
g. MMR second stage regulator. Cover outlet of the

MMR second stage regulator to prevent water, dirt
or debris from entering.

4.  Inspect the entire apparatus as you re-assemble it.

Follow the Inspection Instructions.

5.  Thoroughly dry the facepiece and regulator after

cleaning and disinfecting. The facepiece can trap
water which could enter the regulator.

15

CAUTION

CAUTION

CAUTION

TAL 5010 (L) Rev. 3 - 10037469 

Содержание AirHawk MMR

Страница 1: ...ONS inside For any additional information relative to use or repair write or call 1 800 MSA 2222 during regular working hours See separate insert for NIOSH approval information P N 10039170 For air li...

Страница 2: ...e furnished by the manufacturer under the pertinent approval shall be maintained NIOSH Approval Information is included as a supplement to these instructions P N 10039170 IMPORTANT NOTICE FOR RESPIRAT...

Страница 3: ...safe non haz ardous non toxic atmosphere 5 Return to a safe atmosphere immediately if discol oration crazing blistering cracking or other dete rioration of the lens material is observed 6 Users must w...

Страница 4: ...NOTES 4 TAL 5010 L Rev 3 10037469...

Страница 5: ...nimize the possibility of a first stage failure The regulator uses a large sintered filter which is easy to replace The filter captures particulates that may be in the air stream SECOND STAGE REGULATO...

Страница 6: ...n evenly distributes cylinder weight across the wearer s hips FACEPIECE The facepiece is available in three sizes Only Ultra Elite Hycar facepieces model numbers 7 935 7 7 935 8 and 7 935 9 have been...

Страница 7: ...AND WHISTLE AUDIBLE ALARM CHECKS TESTING 1 Grasp the mask mounted regulator and push the top release button 2 Check that the red bypass knob is fully closed clockwise 3 Reach behind and open the cyli...

Страница 8: ...straps first by pulling them straight back not out Tighten the temple straps the same way Tuck in the ends of the straps so that they lay flat across the head 4 Push headband pad towards neck retighte...

Страница 9: ...ore using the apparatus INSTALLING SLIDE MASK MOUNTED REGULATOR 1 Grasp regulator and orient regulator so that red bypass knob is pointing to the right and slide button is on top 2 Slide regulator ont...

Страница 10: ...return to fresh air The whistle activates when cylinder pressure drops below approximate values 550 psig approximately for low pressure 1125 psig approximately for high pressure when the whistle acti...

Страница 11: ...and pull regulator down and out of facepiece adapter Note Regulator can hang on cover rail in a stand by mode 3 Slide regulator up rail until regulator slide button is free of cover rail 4 Close the c...

Страница 12: ...burst disc and gasket are installed prior to cylinder recharging Establish the service pressure of the cylinder Type 3AA steel cylin ders that bear a plus sign after the latest retest date may be rech...

Страница 13: ...Ice can build up and freeze the buttons bypass valve and the release tabs Before entering or re entering a hazardous atmos phere make sure the buttons release tabs and bypass valve are ice free and op...

Страница 14: ...NOTES 14 TAL 5010 L Rev 3 10037469...

Страница 15: ...e c Rinse the facepiece and components in clean warm 110 F water preferably running and drained d Clean the pressure demand exhalation valve by pressing in on the stem with a blunt object and flushing...

Страница 16: ...NOTES 16 TAL 5010 L Rev 3 10037469...

Страница 17: ...hat the required inspections and tests be performed on all SCBA cylinders in accordance with Department of Transportation DOT regulations DOT reg ulations require that composite cylinders be retired f...

Страница 18: ...NOTES 18 TAL 5010 L Rev 3 10037469...

Страница 19: ...e audible warn ing device be checked by observing the regulator gauge pressure at which the alarms sounds Perform this test with a minimum cylinder pressure of 1 200 psig for the Low Pressure Air Mask...

Страница 20: ...ly and Repair sections and includes installation of the Regulator overhaul kits MSA breathing apparatus must be flow tested every year using an MSA approved flow test device The following table summar...

Страница 21: ...NOTES 21 TAL 5010 L Rev 3 10037469...

Страница 22: ...NOTES 22 TAL 5010 L Rev 3 10037469...

Страница 23: ...parts that after by MSA are proven to be d f defective and or will provided at no cost t F Purchaser s of re to repair not cause the remedy established hereby to fail of its essential purpose MSA r e...

Страница 24: ......

Отзывы: