MSA AirHawk MMR Скачать руководство пользователя страница 1

TAL 5010 (L) Rev. 3

© MSA 2005

Prnt. Spec. 10000005389(A)  Mat. 10037469

Doc. 10000013445

This Self-Contained Breathing Apparatus (SCBA) is certified by the
National Institute of Occupational Safety and Health (NIOSH).

The warranties made by MSA with respect to the product are voided if
the product is not installed, used and serviced in accordance with the
instructions in this manual. Please protect yourself and your employees
by following the instructions. Please read and observe the WARNINGS
and CAUTIONS inside. For any additional information relative to use or
repair, write or call 1-800-MSA-2222 during regular working hours.

See separate insert for NIOSH approval information: P/N 10039170.

For air-line use refer to User’s Instructions P/N 10046412.

THIS MANUAL MUST BE CAREFULLY READ AND FOLLOWED BY ALL
PERSONS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR USING
OR SERVICING THIS AIR MASK. This Air Mask will perform as designed
only if used and serviced according to the instructions; OTHERWISE IT
COULD FAIL TO PERFORM AS DESIGNED, AND PERSONS WHO RELY
ON THE AIR MASK COULD SUSTAIN SERIOUS PERSONAL INJURY OR
DEATH.

WARNING

OPERATION AND INSTRUCTIONS

AirHawk

MMR 

Air Mask

Low/High Pressure

 

Содержание AirHawk MMR

Страница 1: ...ONS inside For any additional information relative to use or repair write or call 1 800 MSA 2222 during regular working hours See separate insert for NIOSH approval information P N 10039170 For air li...

Страница 2: ...e furnished by the manufacturer under the pertinent approval shall be maintained NIOSH Approval Information is included as a supplement to these instructions P N 10039170 IMPORTANT NOTICE FOR RESPIRAT...

Страница 3: ...safe non haz ardous non toxic atmosphere 5 Return to a safe atmosphere immediately if discol oration crazing blistering cracking or other dete rioration of the lens material is observed 6 Users must w...

Страница 4: ...NOTES 4 TAL 5010 L Rev 3 10037469...

Страница 5: ...nimize the possibility of a first stage failure The regulator uses a large sintered filter which is easy to replace The filter captures particulates that may be in the air stream SECOND STAGE REGULATO...

Страница 6: ...n evenly distributes cylinder weight across the wearer s hips FACEPIECE The facepiece is available in three sizes Only Ultra Elite Hycar facepieces model numbers 7 935 7 7 935 8 and 7 935 9 have been...

Страница 7: ...AND WHISTLE AUDIBLE ALARM CHECKS TESTING 1 Grasp the mask mounted regulator and push the top release button 2 Check that the red bypass knob is fully closed clockwise 3 Reach behind and open the cyli...

Страница 8: ...straps first by pulling them straight back not out Tighten the temple straps the same way Tuck in the ends of the straps so that they lay flat across the head 4 Push headband pad towards neck retighte...

Страница 9: ...ore using the apparatus INSTALLING SLIDE MASK MOUNTED REGULATOR 1 Grasp regulator and orient regulator so that red bypass knob is pointing to the right and slide button is on top 2 Slide regulator ont...

Страница 10: ...return to fresh air The whistle activates when cylinder pressure drops below approximate values 550 psig approximately for low pressure 1125 psig approximately for high pressure when the whistle acti...

Страница 11: ...and pull regulator down and out of facepiece adapter Note Regulator can hang on cover rail in a stand by mode 3 Slide regulator up rail until regulator slide button is free of cover rail 4 Close the c...

Страница 12: ...burst disc and gasket are installed prior to cylinder recharging Establish the service pressure of the cylinder Type 3AA steel cylin ders that bear a plus sign after the latest retest date may be rech...

Страница 13: ...Ice can build up and freeze the buttons bypass valve and the release tabs Before entering or re entering a hazardous atmos phere make sure the buttons release tabs and bypass valve are ice free and op...

Страница 14: ...NOTES 14 TAL 5010 L Rev 3 10037469...

Страница 15: ...e c Rinse the facepiece and components in clean warm 110 F water preferably running and drained d Clean the pressure demand exhalation valve by pressing in on the stem with a blunt object and flushing...

Страница 16: ...NOTES 16 TAL 5010 L Rev 3 10037469...

Страница 17: ...hat the required inspections and tests be performed on all SCBA cylinders in accordance with Department of Transportation DOT regulations DOT reg ulations require that composite cylinders be retired f...

Страница 18: ...NOTES 18 TAL 5010 L Rev 3 10037469...

Страница 19: ...e audible warn ing device be checked by observing the regulator gauge pressure at which the alarms sounds Perform this test with a minimum cylinder pressure of 1 200 psig for the Low Pressure Air Mask...

Страница 20: ...ly and Repair sections and includes installation of the Regulator overhaul kits MSA breathing apparatus must be flow tested every year using an MSA approved flow test device The following table summar...

Страница 21: ...NOTES 21 TAL 5010 L Rev 3 10037469...

Страница 22: ...NOTES 22 TAL 5010 L Rev 3 10037469...

Страница 23: ...parts that after by MSA are proven to be d f defective and or will provided at no cost t F Purchaser s of re to repair not cause the remedy established hereby to fail of its essential purpose MSA r e...

Страница 24: ......

Отзывы: