17
Description
GB
Model 9010/9020 SIL
2.8
Digital Interfaces
RS485 Interface
The serial interface RS485 can be used for the connection with SCADA supervision system or
other PLCs, DCS, etc.
The data transmitted on RS485 is half duplex type (38400 / 9600 baud) with Modbus protocol.
See chapter 5.6 for RS485 interface setting.
Refer to Modbus documentation No.D0754156 which can be found on the enclosed CD.
USB Port
The control unit has the USB interface for connecting the control unit to the computer. The USB
interface is reserved for MSA service access only.
Contact MSA for any technical questions. For local MSA contacts go to our website
www.MSAsafety.com.
Ethernet Interface
The control unit has a build in web interface. The web interface allows the operator to see the
controller status. To access the web interface, enter the IP address of the control unit into the
address bar of a web browser. The default username "Customer" and the default password "MSA"
have to be entered to see all information.
See chapter 5.6 for Ethernet interface setting.
Ethernet connection is only available for the wall mounted version due to mechanical reasons.
WARNING!
For safety reasons, the 9010/9020 SIL Ethernet connection and the connected Modbus TCP
Master (SCADA system or PLC) must be used in an own, separated network.