Bottom Menu Programs
Switch to the Programs
Bottom Cleaning
Start cleaning up for press again
Standard Program
The default is two standard programs.
• Program Standard surface part (ONE LAYER)
• Program secondary coating (TWO LAYER)
Bottom On Off
Setting the Current Control
The current regulation has a great influence on the charge on
the powder. As a rule, little electricity is used. Approximately
20 µA. In weakly chargeable powder the amount of current
is set higher. In case of over coating or MDF coating, the
amount of current can be set low. Approximately 8-10 µA.
NOTE
NOTE
In case of excessive amount of electricity
produced orange peel.
If the value falls below the prescribed setting, the module
goes into Tribo alarm, to ensure the desired charge.
ASSIGNMENT OF KEYS
Setting the Gun Air
With the gun air the charging can be controlled. The more
air the more gun powder charge. Settings 0.5 - 2 bar.
0
1
2
3
4
5
6
bar
+
–
0.50
0
2
4
6
12
14
20
8 10
16
18
µA
+
–
3
PROGRAMS
CLEANING
ONE LAYER
TWO LAYER
OFF ON
PA-18-02-R0 (08/2018)
27 / 52
www.carlisleft.com
EN
MAINTENAMCE