Safety Precautions

mrcool.com

Note about Flourinated Gasses (Not applicable to the unit using R290 Refrigerant) 

1.

  

 

WARNING for Using R32/R290 Refrigerant 

WARNINGS FOR PRODUCT INSTALLATION

Installation must be performed by an authorized dealer or specialist. Improper installation can cause water 

leakage, electrical shock, and/or fire.

Installation must be performed according to the installation instructions. Improper installation can cause 

water leakage, electrical shock, and/or fire. In North America, installation must be performed by authorized 

personnel and in accordance with the requirements of the NEC and CEC.

Contact an authorized service technician for repair or maintenance of this unit. This appliance should be 

installed in accordance with national and state wiring regulations.

Only use the included accessories, parts, and specified parts for installation. The use of non-standard, 

aftermarket parts could cause water leakage, electrical shock, fire, and/or cause the unit to fail.
Ensure the unit is installed in a firm, solid location that can support the unit’s weight. If location chosen for 

installation is not able to support the weight of the unit, or the installation is completed improperly, it could 

cause the unit to drop. This could result in serious injury and/or property damage.
Install a drainage pipe according to the instructions provided in this manual. Improper drainage may cause 

water damage to your home or other property.
For units that have an auxiliary electric heater, 

DO NOT

 install the unit within 3 feet (1 m) of any combustible 

materials. 

DO NOT

 install the unit in a location that may be exposed to combustible gas leaks. If combustible gas 

accumulates around the unit, it could cause an explosion, fire, and/or personal injury.

DO NOT

 turn on the power until all work has been completed.

When moving or relocating the air conditioner, consult an experienced service technician for disconnection 

and reinstallation of the unit.
For more information on how to install the indoor and outdoor unit to their supports, please refer to the 

respective indoor and outdoor unit installation sections of this manual. 

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

This air-conditioning unit contains fluorinated greenhouse gasses. For specific information about the type 

of gas, and the amount please refer to relevant label on the unit, or the Manual contained in packaging of the 

outdoor unit.

Installation, service, maintenance, and repair of this unit must be performed by a certified technician.

Product uninstallation and recycling must be performed by a certified technician.

For equipment that contains fluorinated greenhouse gasses in quantities of 5 tonnes of CO

equivalent or 

more, but of less than 50 tonnes of CO2 equivalent, if the system has a leak-detection system installed, it 

must be checked for leaks at least every 24 months.

When the unit is checked for leaks, proper record keeping of all checks is strongly recommended.

1.

2.

3.

4.

When flammable refrigerants are used, the appliance should be stored in a well-ventilated area where the 

room size corresponds to the requirements of room areas specific for operation. Please use the following 

criteria to determine this based on the type of refrigerant used:

 

For R32 refrigerant models: Appliance should be installed, operated, and stored in a room with a 

 

floor area larger than 4m

2

 

 

For R290 refrigerant models: Appliance should be installed, operated, and stored in a room with a 

 

floor area larger than:

   

  

**

For units less than or equal to 9,000 Btu/h: 25.4 m

2

  

  

**

For units greater than 12,000 Btu/h, but less than or equal to 18,000 Btu/h: 26m

2

  

**

For units greater than 18,000 Btu/h , but less than or equal to 24,000 Btu/h: 35m

2

1.

·

·

5.

Содержание Easy Pro Fast Connect

Страница 1: ...o updates and constantly improving performance the information and instructions within this manual are subject to change without notice Please check with your retailer to ensure you have the latest ve...

Страница 2: ...CLAIMER You are assuming the risk by handling materials containing refrigerants under pressure that if not handled properly can cause bodily injury If you do not feel comfortable conducting this insta...

Страница 3: ...Run 38 7 8 9 10 4 Page 2 mrcool com Electrical and Gas Leak Checks 37 Troubleshooting 40 23 1 Prepare Exterior Wall Hole 25 2 Unwind Fast Connect Line Set to necessary length 25 3 Connect Line Set to...

Страница 4: ...s including children with reduced physical sensory or mental capabilities It is also not intended for use by individuals with a lack of experience or knowledge unless they have been given supervision...

Страница 5: ...re and or personal injury DO NOT turn on the power until all work has been completed When moving or relocating the air conditioner consult an experienced service technician for disconnection and rein...

Страница 6: ...ce with all local and national wiring standards regulations and the installation manual Ensure cables are connected tightly and securely clamped to prevent external forces from damaging the terminal I...

Страница 7: ...e electrical shock DO NOT use device for any other purpose than its intended use DO NOT climb onto or place objects on top of the out door unit DO NOT allow the air conditioner to operate for long per...

Страница 8: ...ions in this manual are for explanatory purposes The actual shape of your unit may vary 1 Parts Overview Wall Mounting Plate Power Cable Some Units Refrigerant Piping Signal Cable Remote Controller Dr...

Страница 9: ...Units Functional Filter On Back of Main Filter Some Units Louver Front Panel fresh defrost run timer Display window when Active Clean feature is turned on Displays temperature operation feature and e...

Страница 10: ...pply to the Fast Connect connectors 1 2 3 1 PART QUANTITY LOOKS LIKE 1 1 PART QUANTITY LOOKS LIKE Anchor 5 8 depending on model 5 8 depending on models 1 2 1 2 Battery 1 2 depending on models Small Fi...

Страница 11: ...ELECTRIC HEATER When outside temperature is below 32 F 0 C we strongly recommend keeping the unit plugged in at all times to ensure smooth and continuous performance NOTE If the air conditioner runs...

Страница 12: ...eep away from it as it could cause injury This may also cause the temperature of the room to rise until operation is complete Wireless Control some units Wireless control allows you to control the uni...

Страница 13: ...nit 2 Unplug the unit from the wall outlet 3 Wait a few seconds and plug the unit back in and turn it on 4 This will reset the louver NOTE After a quick restart the vertical louver may remain static f...

Страница 14: ...e remote control was lost The button can be accessed by opening the front panel however the unit must be turned o before the manual operation function can be used CAUTION Manual Control Button To oper...

Страница 15: ...e could cause re or deformation wash air lter with hot water Wipe the unit with a soft dry cloth If the unit is very dirty wipe it with a cloth soaked in warm water DO NOT use bleach or abrasives NOTE...

Страница 16: ...to the previous display To reset the reminder press the LED button on your remote control 4 times or press the MANUAL CONTROL button 3 times If you do not reset the reminder the nF indicator will ash...

Страница 17: ...Location Attach Mounting Plate Determine Wall Hole Position 2 3 Drill Wall Hole Mount Indoor Unit to Mounting Plate Wrap Piping and Cable not applicable for some locations in the US Connect Piping Pre...

Страница 18: ...ar any obstacle that might block air circulation Near a doorway or where outside air may blow directly on indoor unit In a location subject to direct sunlight NOTE ABOUT WALL HOLE If there is no xed r...

Страница 19: ...outdoor units Determine the location of the wall hole based on the position of the mounting plate Refer to the Mounting Plate Dimensions See Fig 4 5 to assist you in determining the optimal position f...

Страница 20: ...ll hole Wall Hole Sleeve Installation Fig 4 4 Fig 4 5 Left rear wall hole 2 5 in 65 mm Left rear wall hole 2 5 in 65 mm Right rear wall hole 2 5 in 65mm Right rear wall hole 2 5 in 65 mm Indoor unit o...

Страница 21: ...and drain hose through the wall hole as you position it to mount to the wall bracket 1 2 3 3 Now you will need to lightly tape the refrigerant piping and drain pipe together in a bundle using electri...

Страница 22: ...combustible gas In a location that is exposed to large amounts of dust In a location exposed to a excessive amounts of salty air In a location that exposes the unit to large amounts of forced water Fi...

Страница 23: ...n hose is as vertical as possible to ensure swift water drainage If water drains too slowly it can freeze in the hose and ood the unit Seal Drain joint only use if elevated A B Base pan hole of outdoo...

Страница 24: ...etween theirmounting feet Prepare the installation base of the unit according to the dimensions in the table below using the illustrations of the unit above Fig 5 5 as a reference guide to correspond...

Страница 25: ...TED UNIT Before installing a wall mounted unit make sure that the wall is made of solid brick concrete or a similarly strong material The wall must be able to support at least 4 times the weight of th...

Страница 26: ...ge the piping while bending it down the exterior wall as this could negatively a ect the performance 3 Step 2 Unwind Fast Connect Line Set to necessary length Carefully unroll to indoor handler connec...

Страница 27: ...coming from the indoor unit or the appropriate line set connector until immediately before you connect them The plastic seals on each of the connectors should be color coded to match the seals of the...

Страница 28: ...mm 1 in 25 4 mm 18 20 lb ft 24 4 27 1 Nm 30 35 lb ft 40 6 47 4 Nm 45 50 lb ft 61 0 67 7 Nm 60 65 lb ft 81 3 88 1 Nm Stamp on connector Coupling Size inch millimeter Maximum Tightening Torque lb ft N m...

Страница 29: ...s carefully Using the rst image below as a guide starting with the bottom screw connector you will now tighten the line set to the outdoor unit Using two appropriate sized open ended wrenches dependin...

Страница 30: ...s in the table below are to be used if you have access to an HVAC torque wrench These are available for purchase from online retailers However it is possible to complete installation of refrigerant li...

Страница 31: ...during the initial check These are imperative to make sure your connections are not allowing refrigerant to escape the system When checking for leaks if any bubbles form it indicates the system has a...

Страница 32: ...containers that collect water This will prevent proper drainage In this step you will connect the drain hose extension to the drain hose exiting from the indoor unit that is within the piping bundle y...

Страница 33: ...ions In this step you will insulate the exposed line connections coming from the indoor air handler with the supplied sound deadening pads and insulation Then wrap the line set from the outdoor unit t...

Страница 34: ...l the unit until the safety issue is properly resolved 4 5 6 7 Only connect the unit to an individual branch circuit outlet Do not connect another appliance to the same circuit as the unit 8 Make sure...

Страница 35: ...HITE BLACK L N OUTDOO UNIT TE MIN L TO INDOO UNIT 208 230 POWER SUPPLY Y G RED 3 2 L1L2 1 3 2 1 WHITE BLACK L1L2 OUTDOO UNIT TE MIN L Fig 7 1 WIRE CONNECTING DIAGRAM 9K 12K Units Connect the MC Cable...

Страница 36: ...is determined by the maximum current of the unit The maximum current is indicated on the nameplate located on the side panel of the unit Cable Types Indoor Power Cable if applicable H05VV F or H05V2V2...

Страница 37: ...block Match up each wire with the correct port and rmly screw the u lug of each wire to its corresponding terminal Now screw the ground wire into the bottom screw of the terminal block as shown in th...

Страница 38: ...there is a leak There are two di erent methods to check for gaseous leaks Please refer to the illustration below for the areas to check for leaks Soap and Water Method Leak Detector Method If using a...

Страница 39: ...properly Indoor unit responds to remote control You should perform the for at least 30 minutes 1 2 Press the button on the remote controller to turn it on 3 Press the button to scroll through the Sel...

Страница 40: ...bient temperature is below 60 F 16 C the remote controller cannot be used to turn on the COOL function In this instance you will need to use the MANUAL CONTROL BUTTON to test the COOL function Follow...

Страница 41: ...nd contraction of the unit s plastic parts Both the indoor unit and outdoor unit make noises Low hissing sound during operation This is a normal sound caused by refrigerant gas owing through both of t...

Страница 42: ...the fuse Remote control batteries are dead Replace the batteries The unit s 3 minute overload protection function has been activated Wait three minutes after restarting the unit Timer is activated Tu...

Страница 43: ...or coil outlet temperature sensor T2B is in open circuit or has short circuited for free match indoor units TS05 ODU 6 times OFF EH 60 Indoor room temperature sensor T1 is in open circuit or has short...

Страница 44: ...uct as household waste or unsorted municipal waste When disposing of this appliance you have the following options Dispose of the appliance at the designated municipal electronic waste collection faci...

Страница 45: ...Installation Owner s Manual Easy Pro Fast Connect...

Отзывы: