Electrical Connections
4.
Now, secure the MC-cable to the outdoor
condenser
by pushing the threaded end of the
cable into the hole and reinstalling the retaining
nut on the end of the cable. Please refer to the
images below.
5.
Then
, you will connect the wires to the terminal
block. Each wire should be numbered and
correspond with a connection port on the terminal
block. Match up each wire with the correct port,
and firmly screw the u-lug of each wire to its
corresponding terminal. Now, screw the ground wire
into the bottom screw of the terminal block, as shown
in the image below.
Ground wire
Connection
6.
Finally, reinstall the electrical wiring cover and secure
it using the 3 screws you removed from it.
Minimum Cr
oss-Sectional A
rea of Power and
Signal Cables (For reference) (Not applicable
for North America)
Rated Current of
Appliance (A)
Nominal Cross-Sectional
Area (mm²)
> 3 and
≤
6
0.75
> 6 and
≤ 10
1
> 10 and ≤
16
1.5
> 16 and
≤ 25
2.5
> 25 and ≤
32
4
> 32 and
≤ 40
6