Wire insertion (Left) and removal (right)
Test:
Inspect that no copper strands are visible in the completed termination
Apply a sharp pull on the wire to ensure that the wire is properly gripped.
3.4) Connection of SA380-IT Supply
The SA380-IT requires an AC supply at the "BX" and "NX" supply terminals to operate.
Tools / Parts Required:
Ferrules
Crimp Tool
2A (minimum) fuse
Actions:
Connect the power supply to the SA380-IT as shown:
The SA380-IT is intended be powered from an AC circuit, however the device will operate when powered from a DC circuit with
appropriate voltage. This is not permitted in UK railway signalling systems.