OnCell G3470A-LTE
Web Console Configuration
3-16
The
Application name
is a text string that describes the corresponding entity with up to 31 characters.
Remember to check the
Active
check box for each entity to activate the setting.
Field
Description
Default setting
Enable
Select
Enable
to enable TCP/UDP port filtering.
Disable
Policy
Select
Accept
to allow packets that meet the specified criteria.
Select
Drop
to deny packets that meet the specified criteria.
Drop
ATTENTION
Be careful when you enable the filter function:
Drop
+ “
no
entity on list is activated” = all packets are
allowed
Accept
+ “
no
entity on list is activated” = all packets are
denied
SNMP Agent
The OnCell G3470A-LTE supports SNMP V1/V2c/V3. SNMP V1 and SNMP V2c use a community string match
for authentication, which means that SNMP servers access all objects with read-only or read/write
permissions using the community string
public
/
private
(default value). SNMP V3, which requires you to
select an authentication level of MD5 or SHA, is the most secure protocol. You can also enable data
encryption to enhance data security.
The OnCell G3470A-LTE’s MIB can be found in the software CD and supports reading the attributes via
SNMP. (Only
get
method is supported.)
SNMP security modes and security levels supported by the OnCell G3470A-LTE are shown in the following
table. Select the security mode and level that will be used to communicate between the SNMP agent and
manager.
Protocol
Version
Setting on
UI web
page
Authentication
Type
Data
Encryption
Method
SNMP
V1, V2c
V1, V2c
Read
Community
Community string No
Use a community string match for
authentication
V1, V2c
Write/Read
Community
Community string No
Use a community string match for
authentication
SNMP V3 No-Auth
No
No
Use account with admin or user to access
objects
MD5 or SHA Authentication
based on MD5 or
SHA
No
Provides authentication based on HMAC-MD5,
or HMAC-SHA algorithms. 8-character
passwords are the minimum requirement for
authentication.