EDS-728 Series User’s Manual
Featured Functions
3-65
Configuring Set Device IP
Desired IP Address
Setting
Description
Factory Default
IP Address
Set the desired IP of connected devices.
None
Using Diagnosis
The EDS-728 provides two important tools for administrators to diagnose network systems.
Mirror Port
The
Mirror port
function can be used to monitor data being transmitted through a specific port.
This is done by setting up another port (the
mirror port
) to receive the same data being transmitted
from, or both to and from, the port under observation. This allows the network administrator to
“sniff” the observed port and thus keep tabs on network activity.