Port Event
Warning e-mail is sent when…
Link-on
The port is connected to another device.
Link-off
The port is disconnected (e.g., the cable is pulled out,
or the opposing device shuts down).
Traffic-Overload
The port’s traffic surpasses the Traffic-Threshold for
that port (provided this item is Enabled).
Traffic-Threshold (%)
Enter a nonzero number if the port’s Traffic-Overload
item is Enabled.
Traffic-Duration (sec.)
A Traffic-Overload warning is sent every
Traffic-Duration
seconds if the average
Traffic-Threshold is surpassed during that time
period.
NOTE
The
Traffic-Overload
,
Traffic-Threshold (%)
, and
Traffic-Duration (sec.)
Port Event items
are related. If you Enable the Traffic-Overload event, then be sure to enter a nonzero
Traffic-Threshold percentage, as well as a Traffic-Duration between 1 and 300 seconds.
NOTE
Warning e-mail messages will have
sender
given in the form:
Moxa_EtherDevice_Switch_0001@Switch_Location
where
Moxa_EtherDevice_Switch
is the default Switch Name,
0001
is the EDS-728’s serial
number, and
Switch_Location
is the default Server Location.
Refer to the Basic
Settings
section to see how to modify Switch Name and Switch Location.