EDS-728 Series User’s Manual
Featured Functions
3-59
Email Alarm Events Settings
Event Types
Event Types can be divided into two basic groups:
System Events
and
Port Events
. System
Events are related to the overall function of the switch, whereas Port Events are related to the
activity of a specific port.
System Event
Warning e-mail is sent when…
Switch Cold Start
Power is cut off and then reconnected.
Switch Warm Start
The EDS-728 is rebooted, such as when network
parameters are changed (IP address, subnet mask,
etc.).
Power Transition (On
Æ
Off)
The EDS-728 is powered down.
Power Transition (Off
Æ
On)
The EDS-728 is powered up.
DI1 (On
Æ
Off)
Digital Input 1 is triggered by on to off transition
DI1 (Off
Æ
On)
Digital Input 1 is triggered by off to on transition
DI2 (On
Æ
Off)
Digital Input 2 is triggered by on to off transition
DI2 (Off
Æ
On)
Digital Input 2 is triggered by off to on transition
Configuration Change Activated Any configuration item has been changed.
Comm. Redundancy Topology
Changed
If any Spanning Tree Protocol switches have changed
their position (applies only to the root of the tree).
If the Master of the Turbo Ring has changed or the
backup path is activated.
Authentication Failure
An incorrect password is entered.