EDS-728 Series User’s Manual
Featured Functions
3-27
Configuring “Turbo Ring V2”
NOTE
When using the Dual-Ring architecture, users must configure settings for both Ring 1 and Ring 2.
In this case, the status of both rings will appear under “Current Status.”
Explanation of “Current Status” Items
Now Active
Shows which communication protocol is in use:
Turbo Ring, Turbo Ring V2, RSTP
, or
none
.
Ring 1/2—Status
Shows
Healthy
if the ring is operating normally, and shows
Break
if the ring’s backup link is
active.
Ring 1/2—Master/Slave
Indicates whether or not this EDS-728 is the Master of the Turbo Ring. (This field appears only
when selected to operate in Turbo Ring or Turbo Ring V2 mode.)
NOTE
The user does not need to set the master to use Turbo Ring. If no master is set, the Turbo Ring
protocol will assign master status to one of the EDS-728 units in the ring. The master is only used
to determine which segment serves as the backup path.