Rate Limiting: Port Disable
Setting
Description
Factory Default
Port disable duration
(1-65535 seconds
When the ingress packets exceed the ingress rate limit, the
port will be disabled for a certain period.
30 seconds
Ingress (frame per
second)
Select the ingress rate (fps) limit for all packets from the
following options: Not Limited, 4464, 7441, 14881, 22322,
37203, 52084, 74405
Unlimited
NOTE
The
Port Disable
function of Rate Limiting is for multicast packets and broadcast packets.
Type 4
For Type 4, the
Control Mode
setting on the
Rate Limiting
page can be set to
Normal
or
Port Disable
.
Control Mode
Setting
Description
Factory Default
Normal
Set the max. ingress rate limit for different packet types
30 seconds
Port Disable
When the ingress multicast and broadcast packets exceed the
ingress rate limit, the port will be disabled for a certain period.
During this period, all packets from this port will be discarded.
Unlimited