![Moxa Technologies EDS-510E Series Скачать руководство пользователя страница 115](http://html1.mh-extra.com/html/moxa-technologies/eds-510e-series/eds-510e-series_user-manual_1842400115.webp)
Moxa Managed Ethernet Switch (UI_2.0_FW_5.x) User Manual
115
Fiber Check
Fiber Check is used to diagnose the link status of fiber connectors, including SFP and fixed type (Multi-mode
SC/ST & Single-mode SC) connectors. Monitor the temperature, TX/RX power, and other parameters on
fiber ports to determine if the ports are working properly. Enable the trap, email warning, and/or relay
warning functions on the System Event Settings page to receive an alarm or relay if one of the fiber ports
exceeds the threshold for that port.
Parameter
Description
Port
Switch port number with a fiber connection.
Model Name
Moxa SFP/fixed type fiber model name.
Wavelength (nm)
Wavelength of the fiber connection.
Vcc (V)
Voltage supply to the fiber connection.
Temperature (°C) – Current Fiber connection current temperature.
Temperature (°C) – Max.
Fiber connection Max. temperature threshold.
Tx power (dBm) – Current
The current amount of light being transmitted into the fiber optic cable.
Tx power (dBm) – Max.
The Max. threshold of light being transmitted into the fiber optic cable.
Tx power (dBm) - Min.
The Min. threshold of light being transmitted into the fiber optic cable.
Rx power (dBm) – Current
The current amount of light being received from the fiber optic cable.
Rx power (dBm) – Max.
The Max. threshold of light being received from the fiber optic cable.
Fiber Check Threshold Values
Model Name
Temperature Threshold
(°C)
Tx Power (Max./Min.) (dBm) Rx Power (Min.) (dBm)
FEMST
120
-11.0/-23.0
-31.0
FEMSC
120
-11.0/-23.0
-31.0
FESSC
120
3.0/-8.0
-34.0
SFP-1FEMLC-T
120
-5.0/-21.0
-37.0
SFP-1FESLC-T
120
3.0/-8.0
-37.0
SFP-1FELLC-T
120
3.0/-8.0
-37.0
SFP-1GSXLC-T
110
-1.0/-12.5
-18.0
SFP-1GLSXLC-T
120
2.0/-12.0
-19.0
SFP-1GLXLC-T
120
0.0/-12.5
-20.0
SFP-1GLHLC-T
120
1.0/-11.0
-23.0
SFP-1GLHXLC-T
120
4.0/-7.0
-24.0
SFP-1GZXLC-T
120
8.0/-3.0
-24.0
SFP-1G10ALC-T
120
0.0/-12.0
-21.0
SFP-1G10BLC-T
120
-5.0/-21.0
-34.0
SFP-1G20ALC-T
120
1.0/-11.0
-23.0
SFP-1G20BLC-T
120
-5.0/-21.0
-34.0
SFP-1G40ALC-T
120
5.0/-6.0
-23.0
SFP-1G40BLC-T
120
-5.0/-21.0
-34.0
SFP-1GSXLC
100
-1.0/-12.5
-18.0
SFP-1GLSXLC
100
2.0/-12.0
-19.0
SFP-1GLXLC
100
0.0/-12.5
-20.0
SFP-1GLHLC
100
1.0/-11.0
-23.0
SFP-1GLHXLC
100
4.0/-7.0
-24.0
SFP-1GZXLC
100
8.0/-3.0
-24.0
SFP-1GEZXLC
100
8.0/-3.0
-30.0