Moxa Managed Ethernet Switch (UI_2.0_FW_5.x) User Manual
24
PTP Settings
Operation
Setting
Description
Factory Default
Enable IEEE 1588 PTP Globally disables or enables IEEE 1588 operation.
Disabled
Clock Mode (sets the switch’s clock mode)
Setting
Description
Factory Default
v1 BC
Operates as an IEEE 1588 v1 boundary clock.
v1 BC
v2 E2E 2-step TC
Operates as an edge-to-edge IEEE 1588 v2 transparent clock
with 2-step method.
v2 P2P 2-step TC
Operates as a peer-to-peer IEEE 1588 v2 transparent clock
with 2-step method.
v2 E2E BC
Operates as an edge-to-edge IEEE 1588 v2 boundary clock
v2 P2P BC
Operates as a peer-to-peer IEEE 1588 v2 boundary clock
SyncInterval (sets the synchronization message time interval)
Setting
Description
Factory Default
0, 1, 2, 3, or 4
0 (1 s), 1 (2 s), 2 (4 s), 3 (8 s), or 4 (16 s). Supported by
IEEE 1588 V1.
0
-3, -2, -1, 0, or 1
-3 (128 ms), -2 (256 ms), -1 (512 ms), 0 (1 s), or 1 (2 s).
Supported in IEEE 1588 V2.
Delay-request Minimum Interval
Setting
Description
Factory Default
0, 1, 2, 3, 4, or 5
Minimum delay request message interval
0 (1 sec.)
Domain
Setting
Description
Factory Default
_DFLT (0), _ALT(1),
_ALT(2), or _ALT(3)
Subdomain name (IEEE 1588-2002) or the domain Number
(IEEE 1588-2008) fields in PTP messages
0(default domain)
Transport mode
Setting
Description
Factory Default
IPv4 or 802.3/Ethernet
IEEE 1588 PTP V1 supports IPv4 only
IEEE 1588 PTP V2 supports both IPv4 and IPv6.
IPv4