![Moxa Technologies EDS-510E Series Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/moxa-technologies/eds-510e-series/eds-510e-series_user-manual_1842400057.webp)
Moxa Managed Ethernet Switch (UI_2.0_FW_5.x) User Manual
57
FDX Flow Ctrl
This setting enables or disables flow control for the port when the port’s Speed is set to Auto. The final
result will be determined by the Auto process between the Moxa switch and connected devices.
Setting
Description
Factory Default
Enable
Enables flow control for this port when the port’s Speed is set
to Auto.
Disabled
Disable
Disables flow control for this port when the port’s Speed is set
to Auto.
MDI/MDIX
Setting
Description
Factory Default
Auto
Allows the port to auto-detect the port type of the connected
Ethernet device and change the port type accordingly.
Auto
MDI
Choose MDI or MDIX if the connected Ethernet device has
trouble auto-negotiating for port type.
MDIX
NOTE
For the Gigabit ports, MDI/MDIX is only Auto mode.
Port Status
The following table shows the status of each port, including the media type, link status, flow control, and
port state.
Link Aggregation
Link aggregation involves grouping links into a link aggregation group. A MAC client can treat link
aggregation groups as if they were a single link.
The Moxa switch’s port trunking feature allows devices to communicate by aggregating up to 4 trunk
groups, with a maximum of 8 ports for each group. If one of the 8 ports fails, the other seven ports will
automatically provide backup and share the traffic.
Port trunking can be used to combine up to 8 ports between two Moxa switches. If all ports on both
switches are configured as 100BaseTX and they are operating in full duplex, the potential bandwidth of the
connection will be 1600 Mbps.