Moxa Managed Ethernet Switch (UI_2.0_FW_5.x) User Manual
31
Syslog Server 1/2/3
Setting
Description
Factory Default
IP Address
Enter the IP address of Syslog server 1/2/3, used by your
network.
None
Port Destination
(1 to 65535)
Enter the UDP port of Syslog server 1/2/3.
514
NOTE
The following events will be recorded into the Moxa switch’s Event Log table, and will then be sent to the
specified Syslog Server:
•
Cold start
•
Warm start
•
Configuration change activated
•
Power 1 or 2 transition: Off to On or On to Off
•
Authentication fail
•
Password change
•
Redundancy protocol/topology change
•
Master setting mismatch
•
ABC-02 status
•
Web log in
•
Rate Limit on/off(Disable port)
•
Port looping
•
Port traffic overload
•
dot1x Auth Fail
•
Port link off/on
Relay Warning Status
When a relay warning is triggered by either the system or port events, the administrator can turn off the
hardware warning buzzer by clicking the
Apply
button. The event will still be recorded in the event list.
NOTE
Relay 1 Alarm Cut-Off (ACO) setting will not be changed by configuration file import.