Moxa Technologies EDS-510E Series Скачать руководство пользователя страница 112

 

 

Moxa Managed Ethernet Switch (UI_2.0_FW_5.x)  User Manual 

112

 

CPU Utilization 

Setting 

Description 

Factory Default 

Read-only 

The CPU usage volume in the past 5 seconds, 30 seconds, and 
5 minutes. When the system is using  less than 50% of CPU 
usage, the first green bar will fill up. When the CPU usage is 
between 51% and 75%, the green and yellow bars will be 
filled. When it exceeds 75%, the system will  be considered 
busy and all green, yellow, and red bars will be filled. 

Past 5 secs 

Free Memory 

Setting 

Description 

Factory Default 

Read-only 

The switch’s  current  free memory 

None 

Power Consumption 

Setting 

Description 

Factory Default 

Read-only 

The current system power consumption  information. The 
measurement tolerance is 7% (Unit:  watts.)  

None 

Statistics 

Access the Monitor by selecting 

Monitoring

  from the left selection  bar. Monitor by System allows the user 

to view a graph that shows the combined data transmission activity  of all of the Moxa switch’s 18 ports. 
Click  one of the four options—

Total  Packets, TX Packets, RX Packets,

 or 

Error Packets

—to view 

transmission  activity of specific types of packets. Recall  that TX Packets are packets sent out from the Moxa 
switch, RX Packets are packets received from connected devices, and Error Packets are packets that did not 
pass TCP/IP’s error checking algorithm. The Total Packets option displays a graph that combines TX, RX, 
and TX Error, RX Error Packet activity. The graph displays data transmission activity by showing 

Packets/s

 

(i.e., packets per second, or pps) versus sec. (seconds). In fact, three curves are displayed  on the  same 
graph:

 Uni-cast 

packets (in  red color), 

Multi-cast 

packets (in green color), and 

Broad-cast

 packets (in 

blue color). The graph is updated every few seconds, allowing the user to analyze data transmission activity 
in real-time. 

 

NOTE 

 

All the statistics are extracted from main chip’s registers sequentially.  Therefore, for a few time  stamps  the 

total packet count may not align  accurately (e.g. Total ≠ sum of Tx + Rx).

 

 

 

Содержание EDS-510E Series

Страница 1: ...this user manual only applies to products using firmware version 5 0 or higher EDS 510E EDS 518E EDS 528E EDS G508E EDS G512E EDS G516E EDS P506E 4PoE EDS G512E 8PoE IKS 6726A IKS 6728A IKS 6728A 8PoE...

Страница 2: ...ent as is without warranty of any kind either expressed or implied including but not limited to its particular purpose Moxa reserves the right to make improvements and or changes to this manual or to...

Страница 3: ...ual LAN VLAN Concept 49 Sample Applications of VLANs Using Moxa Switches 51 Configuring a Virtual LAN 52 VLAN Name Setting 54 QinQ Settings 55 VLAN Table 55 Port 56 Port Settings 56 Port Status 57 Lin...

Страница 4: ...2 SNMP Read Write Settings 103 Trap Settings 104 Industrial Protocols 108 Diagnostics 108 LLDP 108 Ping 109 Port Mirroring 110 Monitoring 111 CPU Memory Utilization 111 Statistics 112 Fiber Digital Di...

Страница 5: ...initial installation process for a Moxa switch Moxa switches provide three interfaces to access the configuration settings USB console interface command line interface and web console interface Chapt...

Страница 6: ...he Internet USB Console Configuration 115200 None 8 1 VT100 NOTE A Moxa switch allows multi session connections up to 6 by connecting to the web console and another console serial or Telnet at the sam...

Страница 7: ...r Ports select the COM port that is being used for the console connection Set the other fields as follows 115200 for Baud Rate 8 for Data Bits None for Parity and 1 for Stop Bits 4 On the Terminal tab...

Страница 8: ...fault the password assigned to the Moxa switch is moxa Be sure to change the default password after you first log in to help keep your system secure 7 The Main Menu of the Moxa switch s USB console sh...

Страница 9: ...onsole your PC host and the Moxa switch must be on the same logical subnet NOTE When connecting to the Moxa switch s Telnet or web console first connect one of the Moxa switch s Ethernet ports to your...

Страница 10: ...field blank and press Enter 4 The Main Menu of the Moxa switch s Telnet console should appear 5 In the terminal window select Preferences from the Terminal menu on the menu bar 6 The Terminal Preferen...

Страница 11: ...a switch s Telnet or web console first connect one of the Moxa switch s Ethernet ports to your Ethernet LAN or directly to your PC s Ethernet port You may use either a straight through or cross over E...

Страница 12: ...ppear Use the folders in the left navigation panel to navigate between different pages of configuration options Disabling Telnet and Browser Access If you are connecting the Moxa switch to a public ne...

Страница 13: ...The Telnet and web consoles can be opened over an Ethernet LAN or the Internet The web console is the most user friendly interface for configuring a Moxa switch In this chapter we use the web console...

Страница 14: ...pplications of different units Example factorySwitch1 none NOTE The Switch Name field follows the PROFINET I O naming rule The name can only include any of these characters a z A Z 0 9 and the name ca...

Страница 15: ...nts including establishing activating modifying disabling and removing accounts There are two levels of configuration access admin and user Accounts with admin authority have read write access of all...

Страница 16: ...e Setting Description Factory Default User Name Max of 30 characters User Name None Password Password for the user account between 4 and 16 characters None Modifying an Existing Account Select an exis...

Страница 17: ...sword is entered The account password policy requires passwords to be of a minimum length and complexity with a strength check If Account Login Failure Lockout is enabled you will need to configure th...

Страница 18: ...twork with multiple segments the switch must be configured with a Global Unicast address Get IP From Setting Description Factory Default DHCP The Moxa switch s IP address will be assigned automaticall...

Страница 19: ...mal values One double colon may be used in the address to indicate the appropriate number of zeros required to fill the undefined fields None IPv6 Global Unicast Address Setting Description Factory De...

Страница 20: ...rmat None Time Zone Setting Description Factory Default Time zone Specifies the time zone which is used to determine the local time offset from GMT Greenwich Mean Time GMT Greenwich Mean Time Daylight...

Страница 21: ...tween the NTP client and NTP server NTP Authentication Settings Setting Description Factory Default Checked Enable NTP Authentication Unchecked Unchecked Disable NTP Authentication Authentication Key...

Страница 22: ...y ID that is used to be authorized Null Clock Source is from SNTP SNTP Client Settings Setting Description Factory Default 1st Time Server The IP or domain address e g 192 168 1 1 time stdtime gov tw...

Страница 23: ...t http ieee1588 nist gov switch htm An Ethernet switch potentially introduces multi microsecond fluctuations in the latency between the 1588 grandmaster clock and a 1588 slave clock Uncorrected these...

Страница 24: ...P2P BC Operates as a peer to peer IEEE 1588 v2 boundary clock SyncInterval sets the synchronization message time interval Setting Description Factory Default 0 1 2 3 or 4 0 1 s 1 2 s 2 4 s 3 8 s or 4...

Страница 25: ...S 6700A and EDS P506E Series do not support the 802 3 setting Role Setting Description Factory Default Member or Master Set this switch to be the Member or Grand Master Member PTP Status Indicates the...

Страница 26: ...Start Power is cut off and then reconnected Warm Start The Moxa switch is rebooted such as when network parameters are changed IP address subnet mask etc Configuration Change Any configuration item h...

Страница 27: ...en changed Configuration is Imported When the configuration is successfully imported SSL Certification is Imported When SSL Certification is successfully imported Fiber Check Warning If the correspond...

Страница 28: ...on Trap The EDS E series will send a notification to the trap server when an event is triggered E Mail The EDS E series will send a notification to the email server defined in the Email Setting Syslog...

Страница 29: ...size Action Setting Description Factory Default Overwrite The Oldest Event Log The oldest event log will be overwritten when the event log exceeds 1000 records Overwrite The Oldest Event Log Stop Reco...

Страница 30: ...mplete the email settings you should first click Apply to activate those settings and then press the Test button to verify that the settings are correct NOTE Auto warning e mail messages will be sent...

Страница 31: ...tart Configuration change activated Power 1 or 2 transition Off to On or On to Off Authentication fail Password change Redundancy protocol topology change Master setting mismatch ABC 02 status Web log...

Страница 32: ...ss groups which are selected from the drop down list Drop Down List ALL Select this item to show all of the Moxa switch s MAC addresses ALL Learned Select this item to show all of the Moxa switch s Le...

Страница 33: ...moxa com 2 Browse for the rom file and then click the Upgrade button TFTP Server 1 Enter the TFTP Server s IP address 2 Input the firmware file name rom and click the Upgrade button Auto Backup Confi...

Страница 34: ...ick the Backup Restore button Auto Backup Configurator ABC 02 1 Click Backup to save the configuration file to the ABC 02 The file will be saved in the ABC 02 s Moxa folder as a ini file e g Sys ini N...

Страница 35: ...02 when configuration change checkbox and then click Apply This function is disabled by default The ABC 02 is capable of backing up switch configuration files automatically While the ABC 02 is plugge...

Страница 36: ...es the following information Index An event index assigned to identify the event sequence Bootup Number This field shows how many times the Moxa switch has been rebooted or cold started Date The date...

Страница 37: ...led Turbo Ring v2 protocol will be enabled when the DIP switch is moved to the ON position NOTE If the 4th DIP switch Turbo Ring is configured to ON you will not be able to disable the Turbo Ring DIP...

Страница 38: ...rge part to the reliability provided by PoE Ethernet switches that supply the power to Powered Devices PD when AC power is not available or is too expensive to provide locally Power over Ethernet can...

Страница 39: ...rface gives users control over the system s PoE power output PoE power threshold PoE port configuration and PD failure check The PoE settings page is divided into three parts PoE System Configuration...

Страница 40: ...oE power transmission to a PD Enable Disable Disables PoE power transmission to a PD PoE power management Mode Setting Description Factory Default Allocated Power If a powered device is connected that...

Страница 41: ...tance range is 17 k to 29 k and the power allocation of the port is automatically set to 36 W Force 2 Pair Force 36W only for EDS P506E 4PoE Provides power output to non 802 3 af at PDs The acceptable...

Страница 42: ...s When the PoE measured power exceeds the assigned limit the switch will disable the PoE port with the lowest priority Setting Description Factory Default 1 to number of PoE ports The smaller the numb...

Страница 43: ...Checked Select those days on which you would like the port to be enabled you will then be able to modify the StartTime and EndTime Disable Unchecked The port will not provide PoE power on days that a...

Страница 44: ...its 802 3 af 350 mA 802 3 at 600 mA High Power 720 mA Force 600 mA PoE PD Failure Check When the switch does not receive a PD response after the defined period Over Measured Power Limitation When the...

Страница 45: ...f 802 3 at or legacy 2 pair PD 4 Pair 60W A 4 Pair PD that uses all 8 pins of the RJ 45 connector to receive PoE output Classification Item Description N A The port is not classified 0 to 4 Class 0 to...

Страница 46: ...4 Pair PD the system suggests selecting 4 Pair High Power 60W mode Select 2 Pair Force Mode or 4 Pair Force Mode When configuring at 4 Pair PoE Mode and detecting higher lower resistance or higher ca...

Страница 47: ...a legacy PD Potential Legacy PD In 802 3af at or High Power mode the system has detected a potential legacy PD PoE power is not being provided Port Description Item Description Status Indicates if th...

Страница 48: ...er Status shows a graph of Sum of measured power Sum of allocated power and Max of allocated power Sum of measured power in green shows the total measured power of all PDs Sum of allocated power in bl...

Страница 49: ...flexible than traditional networks Using VLANs also provides you with three other benefits VLANs ease the relocation of devices on networks With traditional networks network administrators spend much...

Страница 50: ...a single VLAN it can be an untagged member but if the port needs to be a member of multiple VLANs a tagged membership must be defined A typical host e g clients will be an untagged member of one VLAN...

Страница 51: ...it should be configured as an Access Port with PVID 5 Port 7 connects a single untagged device and assigns it to VLAN 4 it should be configured as an Access Port with PVID 4 After the application is p...

Страница 52: ...sed to configure the settings for individual ports Quick Setting Panel The EDS E series provides a Quick Setting Panel that administrators can use to quickly configure VLAN settings for single ports o...

Страница 53: ...PVID Setting Description Factory Default 1 to 4094 Sets the default VLAN ID for untagged devices connected to the port 1 Tagged VLAN Setting Description Factory Default 1 to 4094 This field will be ac...

Страница 54: ...ximum VLAN ID equals the number of switch ports In the following example all of the ports are assigned to VLAN 1 NOTE Port Based VLAN is supported by EDS series switches not including the EDS 728 828...

Страница 55: ...ws users to tag double VLAN headers into a single Ethernet frame TPID Setting Description Factory Default 8100 to FFFF Assign the TPID of the second VLAN tag 8100 QinQ Enable Setting Description Facto...

Страница 56: ...type Displays the media type for each module s port N A Description Setting Description Factory Default Max 63 characters Specifies an alias for the port to help administrators differentiate between...

Страница 57: ...net device has trouble auto negotiating for port type MDIX NOTE For the Gigabit ports MDI MDIX is only Auto mode Port Status The following table shows the status of each port including the media type...

Страница 58: ...ured as 100BaseTX and they are operating in full duplex mode the potential bandwidth of the connection will be up to 1 6 Gbps This means that users can double triple or quadruple the bandwidth of the...

Страница 59: ...ol Protocol Static NOTE Trunk groups could also be selected as the redundant ports for Turbo Ring V2 or Turbo Chain Trunking Status The Trunking Status table shows the Trunk Group configuration status...

Страница 60: ...acket has a multicast group address in the destination address field of the packet s IP header Benefits of Multicast The benefits of using IP multicast are It uses the most efficient sensible method t...

Страница 61: ...onging to the same group Multicast Filtering and Moxa s Industrial Rackmount Switches There are three ways to achieve multicast filtering with a Moxa switch IGMP Internet Group Management Protocol Sno...

Страница 62: ...ffic for the multicast groups When the router forwards traffic for the multicast group to the LAN or VLAN the switches only forward the traffic to ports that received a report packet IGMP version 3 su...

Страница 63: ...LAN is enabled IGMP Snooping Setting Enable IGMP Snooping Global Setting Description Factory Default Enable Disable Select the Enable IGMP Snooping checkbox near the top of the window to enable the IG...

Страница 64: ...l connect to the multicast routers These ports will receive all multicast packets from the source This option is only active when IGMP Snooping is enabled Disabled NOTE If a router or layer 3 switch i...

Страница 65: ...eives the multicast stream or the port the multicast stream is forwarded to Version Displays the IGMP Snooping version Filter Mode Indicates that the multicast source address is included or excluded D...

Страница 66: ...y Default Integer Type the MAC address in the MAC Address field to specify a static multicast address None Member Port Setting Description Factory Default Select Deselect Select the appropriate checkb...

Страница 67: ...rt This multicast address is learned by GMRP Multicast Filtering Behavior Multicast Filtering Behavior supports two options Forward Unknown and Filter Unknown Note Only supported by the EDS 518E EDS 5...

Страница 68: ...al applications Provide predictable throughput for multimedia applications such as video conferencing or voice over IP and minimize traffic delay and jitter Improve network performance as the amount o...

Страница 69: ...d consequently traffic will only contain 802 1p priority markings if the network is configured with VLANs and VLAN tagging The traffic flow through the switch is as follows A packet received by the Mo...

Страница 70: ...lied to the four priorities This approach prevents the lower priority frames from being starved of opportunity for transmission with only a slight delay to the higher priority frames Weight Fair Stric...

Страница 71: ...er can enable these classifications individually or in combination For instance if a hot higher priority port is required for a network design TOS DSCP Inspection and Cos Inspection can be disabled Th...

Страница 72: ...User Manual 72 Priority Mapping Type 2 CoS Value and Priority Queues Setting Description Factory Default 0 to 7 Maps different CoS values to 8 different egress queues CoS 0 0 CoS 1 1 CoS 2 2 CoS 3 3 C...

Страница 73: ...y unpredictable faults Traffic Rate Limiting Settings There are four types of bandwidth management settings depending on which model of switch you are using Type Model Type 1 EDS 510E Type 2 EDS G508E...

Страница 74: ...of max throughput for all packets from the following options Not Limited 3 5 10 15 25 35 50 65 85 Unlimited Rate Limiting Port Disable Setting Description Factory Default Port disable duration 1 6553...

Страница 75: ...s packets Drop Packet Port Disable When the ingress packets exceed the ingress rate limit the port will be disabled for a certain period During this period all packets from this port will be discarded...

Страница 76: ...ng Description Factory Default Drop Packet Set the max ingress egress rate limit for ingress egress packets Drop Packet Port Disable When the ingress packets exceed the ingress rate limit the port wil...

Страница 77: ...464 7441 14881 22322 37203 52084 74405 Unlimited NOTE The Port Disable function of Rate Limiting is for multicast packets and broadcast packets Type 4 For Type 4 the Control Mode setting on the Rate L...

Страница 78: ...ons Unlimited 128K 256K 512K 1M 2M 4M 8M 10 100Mbps 15 150Mbps 25 250Mbps 35 350Mbps 50 500Mbps 65 650Mbps 85 850Mbps Limit Broadcast 8M Limit Broadcast Multicast Flooded Unicast Limit Broadcast Multi...

Страница 79: ...ted 4464 7441 14881 22322 37203 52084 74405 Unlimited Security Security can be categorized into two levels the user name password level and the port access level Moxa switches provide many kinds of se...

Страница 80: ...the appropriate checkboxes to enable Moxa Service NOTE Moxa Service is only for Moxa network management software suite TCP Port 4000 UDP Port 4000 Enable Moxa Service Encrypted Setting Description Fa...

Страница 81: ...o 192 168 1 1 only Grant access to any host on a specific subnetwork For example enter IP address 192 168 1 0 with netmask 255 255 255 0 to allow access to all IPs on the subnet defined by this IP add...

Страница 82: ...rd PKCS 12 certificate file 2 Enter the Import Password and click Import 3 The SSL certificate is updated Regenerate SSL Certificate Setting Description Factory Default Select Deselect Enable the SSL...

Страница 83: ...local database 2 RADIUS Local Check RADIUS database first If the RADIUS server is not reachable then the switch will check the local database 3 TACACS Only check TACACS database 4 RADIUS Only check th...

Страница 84: ...and responds to the requests from the switch Authentication Server The server that performs the actual authentication of the supplicant Authenticator Edge switch or wireless access point that acts as...

Страница 85: ...ase as the authentication database Re Auth Global Setting Description Factory Default Enable Disable Select enable to require re authentication of the client after a preset time period of no activity...

Страница 86: ...AC Authentication Bypass with the Local database None Description Max of 30 characters Description for the Local User Database None NOTE The user name for the IEEE 802 1X Local Database is not case se...

Страница 87: ...thentication Bypass column to enable MAC Authentication Bypass for one or more ports Deselect NOTE If RADIUS Server is case sensitive use lower case characters for the username and password NOTE MAC A...

Страница 88: ...to access a port after the maximum number of MAC addresses have already been learned The total number of allowed MAC addresses cannot exceed 1024 NOTE The whitelist or blacklist of the EDS G500E Seri...

Страница 89: ...limit is reached and the port receives a packet with an unknown MAC address unlearned by the port the packet will be discarded Disable Enable When the port limit is reached and the port receives a pa...

Страница 90: ...None MAC Address Sticky Port Number Setting Description Factory Default Port Number Associates the static address to a dedicated port None VID Setting Description Factory Default VLAN ID Associates th...

Страница 91: ...escription Factory Default Unchecked Broadcast storm protection is not activated Checked Checked Broadcast storm protection is activated In this case you may check either one or both of Include Multic...

Страница 92: ...wing layer 2 switches EDS 518E EDS 528E EDS G508E EDS G512E EDS G516E EDS G512E 8PoE the IKS Series and the ICS Series Layer 2 switches only support Ingress ACL Access control lists ACLs increase the...

Страница 93: ...ules In other words Access Control Lists have Priority Index as an attribute to define the priority in the web configuration console There are two types of settings for an ACL list settings and rule s...

Страница 94: ...d Note that the ACL ID is not unique with respect to the profile name The ID changes when swapping the priority of different access control profiles The maximum Priority Index number is 16 Name You ca...

Страница 95: ...you would like to edit based on the ACL ID and then set up the rule content and ingress egress ports After configuring click the Add button to add the rule to the list Finally click Apply to activate...

Страница 96: ...ranges to filter It allows checking the source or destination of the packet Choose Any if you do not need to use this criteria IP Protocol Select the type of protocols to be filtered Moxa provides IC...

Страница 97: ...Moxa Managed Ethernet Switch UI_2 0_FW_5 x User Manual 97 MAC Based Layer 2 Device NOTE MAC based ACL is not available on the EDS 510E Series...

Страница 98: ...ific MAC address ranges to filter It allows checking the source or destination of the packet Choose Any if you do not need to use this criterion Ethernet Type Select the type of Ethernet protocol to f...

Страница 99: ...select Port or ACL ID and all the rules will be displayed in the table DHCP IP Port Binding Designated IP Address Setting Description Factory Default IP Address Set the desired IP of connected devices...

Страница 100: ...ons Circuit ID and Remote ID which define the relationship between the end device IP and the DHCP Option 82 server The Circuit ID is a 4 byte number generated by the Ethernet switch a combination of p...

Страница 101: ...tion 82 function Disable Assign Remote ID by Setting Description Factory Default IP Uses the switch s IP address as the remote ID sub IP MAC Uses the switch s MAC address as the remote ID sub IP Clien...

Страница 102: ...hentication V1 V2c Write Read Community Community string No Uses a community string match for authentication SNMP V3 No Auth No No Uses an account with admin or user to access objects MD5 or SHA Authe...

Страница 103: ...ccount to access objects without authentication No MD5 Auth Authentication will be based on the HMAC MD5 algorithms 8 character passwords are the minimum requirement for authentication No SHA Auth Aut...

Страница 104: ...MP Trap V1 Trap V2c Host IP Address 1 Setting Description Factory Default IP or name Specifies the IP address or name of the primary trap server used by your network None 1st Trap Community Setting De...

Страница 105: ...on the HMAC MD5 algorithms 8 character passwords are the minimum requirement for authentication SHA Auth Authentication will be based on the HMAC SHA algorithms 8 character passwords are the minimum r...

Страница 106: ...Factory Default IP or name Specifies the IP address or name of the primary trap server used by your network NA 1st Trap Community Setting Description Factory Default Max 30 characters Specifies the co...

Страница 107: ...on the HMAC MD5 algorithms 8 character passwords are the minimum requirement for authentication SHA Auth Authentication will be based on the HMAC SHA algorithms 8 character passwords are the minimum r...

Страница 108: ...t tools for administrators to diagnose network systems LLDP Ping and Port Mirror LLDP Overview LLDP is an OSI Layer 2 protocol defined by IEEE 802 11AB LLDP standardizes the self identification advert...

Страница 109: ...vice Neighbor Port The port number of the neighbor device Neighbor Port Description A textual description of the neighbor device s interface Neighbor System Hostname of the neighbor device Ping The Pi...

Страница 110: ...EDS 510E EDS 518E EDS 528E EDS P506E 4PoE IKS 6726A IKS 6728A IKS 6728A 8PoE IKS G6524A IKS G6824A ICS G7526A ICS G7826A ICS G7528A ICS G7828A ICS G7748A ICS G7848A ICS G7750A ICS G7850A ICS G7752A I...

Страница 111: ...itor only those data packets being sent out through Moxa s switch TX RX Select this option to monitor data packets both coming in and being sent out through Moxa s switch Mirror Port Select the number...

Страница 112: ...mbined data transmission activity of all of the Moxa switch s 18 ports Click one of the four options Total Packets TX Packets RX Packets or Error Packets to view transmission activity of specific type...

Страница 113: ...ical display of the individual port activity that can be viewed with the Console Monitor function discussed above The All Ports option shows three vertical bars for each port The height of the bar rep...

Страница 114: ...ugging Two different categories of Moxa switches support Fiber Digital Diagnostics Monitoring functions SFP DDM and Fiber Check Type Models Supported SFP DDM IKS 6726A IKS 6728A IKS 6728A 8PoE IKS G65...

Страница 115: ...shold of light being transmitted into the fiber optic cable Tx power dBm Min The Min threshold of light being transmitted into the fiber optic cable Rx power dBm Current The current amount of light be...

Страница 116: ...rtain tolerances exist between real data and measured data Event Log The Event Log Table displays the following information Index Event index assigned to identify the event sequence Bootup Number This...

Страница 117: ...and the availability of a host by pinging it The status of tracking up down is the result of the monitored target The tracking function can bind a tracking entry and perform a specific action accordi...

Страница 118: ...interface 1 000 ms Up Delay ms Setting Description Factory Default 0 to 100 000 ms The threshold that the status of interface tracking changes from down to up when the status of the monitored port or...

Страница 119: ...cking ID of ping tracking No NOTE The tracking ID has to be unique IP Address Setting Description Factory Default Valid IP address The monitored IP address No Interval ms Setting Description Factory D...

Страница 120: ...f the logic tracking entry is up Otherwise the status of the logic tracking entry is down With operator OR if all the statuses of the entries in the Logical List are down the status of the logic track...

Страница 121: ...acking Select this item to show all the interface tracking information Ping Tracking Select this item to show the ping tracking information Logical Tracking Select this item to show the logical tracki...

Страница 122: ...s follows MIB II 1 System Group sysORTable MIB II 2 Interfaces Group ifTable MIB II 4 IP Group ipAddrTable ipNetToMediaTable IpGroup IpBasicStatsGroup IpStatsGroup MIB II 5 ICMP Group IcmpGroup IcmpIn...

Страница 123: ...tic dot1qStaticUnicastTable dot1qStaticMulticastTable dot1qVlan dot1qVlanCurrentTable dot1qVlanStaticTable dot1qPortVlanTable The private MIB file can be downloaded from Moxa s website www moxa com Pu...

Отзывы: