Moxa Managed Ethernet Switch (UI_2.0_FW_5.x) User Manual
44
Warning Type
Action
Description
Trap
The EDS E series will send a notification to the trap server when
an event is triggered.
The EDS E series will send a notification to the email server
defined in Email Settings.
Syslog
The EDS E series will record a syslog to a syslog server defined in
Syslog Server Settings.
Relay1
The EDS E series supports digital inputs to integrate sensors.
When an event is triggered, the device will automatically activate
an alarm through the relay output.
Event Type
Port Events
Description
PoE PD power on
Power is being output to the PD.
PoE PD power off
The PoE power output is cut off.
PoE over current
When the current of the port exceeds the following limits:
802.3 af:
350 mA
802.3 at:
600 mA
High Power: 720 mA
Force:
600 mA
PoE PD Failure Check
When the switch does not receive a PD response after the defined
period.
Over Measured Power Limitation
When the total PD power consumption exceeds the total
measured power limit.
PoE FETBad
When the MOSFET of the port is out of order (please contact
Moxa for technical service)
PoE over Temperature
Check the temperature of the environment. If you cannot keep
the temperature under 75°C, contact Moxa for technical support.
PoE VEE Uvlo - VEE (PoE input voltage)
under Voltage Lockout
The voltage of the power supply has dropped below 44 VDC.
Adjust the voltage to between 46 and 57 VDC to eliminate this
issue.
Over Allocated Power Limitation
When the total PD power consumption exceeds the total allocated
power.
NOTE
The Relay Output does not support three Event Types:
External FET has failed, PSE chip is over
temperature
, and
V
EE
(PoE input voltage) under voltage lockout
.