- 9 -
limited power source. When AWK-6232-M12 is powered via DC power,
the M12 A-coding connector on the bottom panel is used for the
AWK-6232-M12’s two redundant inputs. The male, device-side pin
assignment is shown below:
Pin
Power Input
1
V1+
2
V2+
3
V1-
4
V2-
5
GND
ATTENTION
This product is intended to be supplied by a Listed Power Unit
marked “Class 2” or “LPS” and rated O/P: 12 to 48 VDC,
maximum 800mW.
Make sure External Power Adaptor (includes power cords and
plug assemblies) provided with the unit is certified and suitable
for use in your country.
Before connecting the AWK-6232-M12 to the DC power inputs,
make sure the DC power source voltage is stable.
ATTENTION
Do not use the PoE Injector. Instead, please use an IEEE802.3af
or IEEE802.3at compliant PSE (Power Sourcing Equipment) for
PoE+ (Power over Ethernet Plus) devices.
Wiring the Digital Inputs and Relay Contact
(Digital Output)
The AWK-6232-M12 has two sets of digital input—DI1 and DI2. Each DI
comprises two contacts of the 8-pin M12 connector on the
AWK-6232-M12’s bottom panel. These two digital inputs can be
connected to digital-output-enabled sensors for on-site status
monitoring.
The AWK-6232-M12 also has one relay output, which consists of the two
contacts. These relay contacts are used to detect user-configured events.
The two wires attached to the Relay contacts form an open circuit when a
user-configured event is triggered. If a user-configured event does not
occur, the Relay circuit will be closed.