- 12 -
NOTE
1.
The pin numbers for male DB9 and DB25 connectors, and
hole numbers for female DB9 and DB25 connectors are
labeled on the connector. However, the numbers are
typically quite small, so you may need to use a magnifying
glass to see the numbers clearly.
2.
The pin numbers for both 8-pin and 10-pin RJ45 connectors
(and ports) are typically not labeled on the connector (or
port). Refer to the Pinout diagram above to see how RJ45
pins are numbered.
ATTENTION
For railway rolling stock applications, AWK-6232-M12 devices
must use a galvanically isolated power supply that is compliant
with the EN 50155 standard.
LED Indicators
The front panel of the Moxa AWK-6232-M12 contains several LED
indicators. The function of each LED is described in the table below.
LED
Color
State
Description
PWR
Green
On
Power is being supplied
(from power input 1 or 2, or PoE)
Off
Power is not being supplied
FAULT
Red
Blinking
(slow)
Cannot get an IP address from the DHCP
server (interval: 1 sec)
Blinking
(fast)
IP address conflict (interval: 0.5 sec)
Off
Error condition does not exist
STATE
Green/Red Green
Software Ready
Green,
blinking
The AWK has been located by AWK
Search Utility. (interval: 1sec)
Red
Booting or Error condition
WLAN 1
and
WLAN 2
Green/
Amber
Green,
on
Device is connected to a WLAN in
Client/Slave
mode
Green,
blinking
Device is transmitting WLAN data in
Client/Slave
mode
Amber,
on
Device is connected to a WLAN in
AP/Master
mode
Amber,
blinking
Device is transmitting WLAN data in
AP/Master
mode
Off
WLAN is not in use or not working
properly