- 15 -
Digital Inputs (M12
female connector):
2 electrically isolated
inputs
• +13 to +30 V for state “1”
• +3 to -30 V for state “0”
• Max. input current: 8 mA
Physical Characteristics
Housing:
Metal, IP68 protection
Weight:
1.8 kg
Dimensions:
224 x 147.7 x 64.5 mm (8.82 x 5.82 x 2.54 in)
Installation:
Wall mounting (standard), DIN-Rail mounting
(optional), pole mounting (optional)
Environmental Limits
Operating
Temperature:
-40 to 75°C (-40 to 167°F)
Storage
Temperature:
-40 to 85°C (-40 to 185°F)
Ambient Relative
Humidity:
5% to 100% (non-condensing)
Power Requirements
Input Voltage:
12 to 48 VDC, redundant dual DC power inputs or
48 VDC Power over Ethernet Plus (IEEE 802.3at
compliant)
Connector:
M12 connector (male) with A-coding
Power Consumption Power Consumption: 12 to 48 VDC, 1.5 A (max.)
Reverse Polarity
Protection:
Present
Standards and Certifications
Safety:
UL 60950-1, EN 60950-1
EMC:
EN 301 489-1/17; FCC Part 15, Subpart B;
EN 55022/55024
Radio:
EN 300 328, EN 301 893, DSPR (Japan)
Rail Traffic:
EN 50155, EN 50121-1/4
Note:
Please check Moxa’s website for the most recent
certification status.
Warranty
Warranty Period: 5 years
Details: See www.moxa.com/warranty
RESTRICTED ACCESS ONLY
This equipment is intended to be installed only in
restricted access
locations
such as server rooms with limited access to SERVICE
PERSONNEL or USERS who have not been instructed on how to handle the
device. During normal operations,
this device can reach
temperatures high enough to require special protection before
handling
. Installation locations should be within locked, confined spaces
that are accessible only with a key or through security identification
systems.
The external metal parts of this equipment will get extremely hot!!
Before handling, service personnel must take special precautions to
protect hands and body from serious injury.