WARNINGS
All
warnings
are self eliminating, except Error code 05.
It is possible to cancel an warning, but when the error remains, the warning will return after 60
seconds. This gives the operator the time to solve the problem without having the alarm on.
Error 00
“Low hopper level” [free programmable]
If this warning appears the material in the hopper is below the hopper empty weight (700 gr.)
In CONFIGURATION <menu> this setting can be changed.
- Check if there’s enough material in the hopper.
- Check the hopper empty setting in CONFIGURATION <menu>
- Check if the hopper loader is working right.
Error 01
“Maximum deviation exceeded” [free programmable]
If this warning appears the dosing output (grams/sec) is consistently not within set percentage. See page
18 for more information.
Error 02
“Filling system unable to load material”
If this warning appears the alarm time (ME hopper loader) or alarm cycles (MV hopper loader) are
exceeded.
- Check if there is enough material.
- Check if the material is stuck somewhere.
- Check the operation of the hopper loader.
- Check the hopper loader settings.
Error 03
“Maximum RPM exceeded, change dosing tool for higher capacity”
Calculated motor speed is higher than the maximum of 200 RPM
- Check the material output on 200 RPM.
- Check the production settings.
- Increase the dosing time (if possible)
- Take another dosing type with higher output, for example a feed screw A20
Error 05
“Calibration, no weight change”
No weight change while calibrating (see chapter 7.6)
- Check if there’s enough material in the hopper.
- Check if the material is stuck in the dosing cylinder.
- Check if the load cell is connected correctly.
- Check the weight data by doing a weight check (see chapter 7.5)
- Check if there are no vibrations that may have influence.
- Check the rotation direction of the dosing cylinder. Front view to the right
Error 06
“EX-Hi Hi level”
- Check if the knife gate valve is in closed position.
- Check if the knife gate is sliding.
- Check if the parameters EX-H level and EX-HH level are set OK.
Error 07
“Minimum motor speed < 0,1 RPM”
Calculated motor speed is lower than the minimum of 0,5 RPM
- Check if there’s enough material in the hopper.
- Check the production settings.
- Decrease the dosing time (if possible)
- Take an other dosing type with lower output, for example a GL-cylinder
- Check the rotation direction of the dosing cylinder. Front view to the right
ALARMS
Error 08
“Motor connection failure”
Motor connection is not correct.
- Make sure the motor is connected.
- Check cable and connectors for damage.
Error 09
“Parameters damaged”
Some configuration parameters are incorrect.
- Check the configuration parameters.
Error 10
“Parameters set to factory defaults”
All parameter settings are reset to factory defaults.
- Check all parameter settings.
Error 11
“Load cell calibration set to factory defaults”
Load cell calibration is incorrect and reset to factory defaults.
- Recalibrate the load cell !
Error 12
“Jobs and curve database initialized”
All Jobs and materials are reset
- Make new material calibrations and Jobs.
Error 13
“Loadcell connection failure”
-Load cell connection is not correct.
-Load cell connector is not connected to the controller.
Содержание MC-BALANCE
Страница 1: ...MC Balance User Manual 4 0 UK 00 Software version V4 0 Manual revision 0 0 Date April 2008 ...
Страница 2: ......
Страница 47: ...MC Balance manual 44 General dimension MC Balance ME25G NST40 Neckpiece ...
Страница 48: ...MC Balance manual 45 General dimension MC Balance MV25G NST40 Neckpiece ...
Страница 49: ...MC Balance manual 46 General dimension MC Balance Support frame NST40 Neckpiece ...