MC-Balance manual
31
General
The hopper loader is only activated when the motor is On .
Emergency stop.
To stop the hopper loader during production go to the HOPPER LOADER <menu> and switch the
ME or MV system to
OFF
.
Hopper loader settings
This part of the manual describes how to configure the hopper loader. For further technical
information about the hopper loader consult the specific hopper loader manual.
There are four ways to fill the hoppers:
1. Manual
2. Automatic with ME hopper loader
3. Automatic with MV hopper loader
4. Automatic with EX external hopper loader in combination with the support frame.
Manual
Open the hopper lid and fill the hopper by hand. (filling will be detected automatically)
The message “Low hopper level” appears when the hopper is empty.
(default 700 gr. In CONFIGURATIONS <menu>)
ME hopper loader (Movacolor hopper loader operated by compressed air)
Highlighted Parameters are factory settings.
MV hopper loader (Movacolor hopper loader operated by vacuum)
Highlighted Parameters are factory settings.
ME FILLING SYSTEM
ME system : OFF/ON
Fill time : 30 sec
Alarm time : 31 sec
Alarm mode : OFF/ON
Manual fill: NO/YES
MV FILLING SYSTEM
MV system : OFF/ON
Fill time : 20 sec
Empty time : 05 sec
Fill cycles : 3 x
Alarm cycles: 10 x
Alarm mode : OFF/ON
Manual fill: NO/YES
ME system:
Switch ON / OFF the ME hopper loader system
Fill time:
Fill time [sec.], during this time the system blows material into the hopper of the
dosing unit.
Alarm time:
Fill Alarm [sec.], if the hopper weight is not above the 800gr. within this time, the
alarm starts. The alarm time can not set lower than the fill time.
Alarm mode:
ME hopper loader is ON / OFF during fill alarm.
ON
= ME Hopper loader stays activated during a filling alarm.
OFF
= ME Hopper loader will be deactivated during a filling alarm.
Manual fill:
Yes = starting filling immediately;
No = stop filling immediately
Only visible with controller in STOP mode.
The Manual filling function can be used for example to fill the hopper before start
of production.
MV system:
Switch ON / OFF the MV hopper loader system
Fill time:
Fill time [sec.], during this time the MV system sucks material into the vacuum
chamber.
Empty time:
Empty time [sec.], during this time the cone that closes the chamber will open
and material falls down into the hopper of the dosing unit.
Fill cycles:
Number of extra fill cycles after the hopper weight is above the 800gr. again
Alarm cycles:
Number of idle fill cycles before fill alarm. The number of alarm cycles needs to
be more than the number of Fill. cycles.
Alarm mode:
MV hopper loader is ON / OFF during fill alarm.
ON
= ME Hopper loader stays activated during a filling alarm.
OFF
= ME Hopper loader will be deactivated during a filling alarm.
Manual fill:
Yes = starting filling immediately;
No = stop filling immediately
Only visible with controller in STOP mode.
The Manual filling function can be used for example to fill the hopper before start
of production.
Содержание MC-BALANCE
Страница 1: ...MC Balance User Manual 4 0 UK 00 Software version V4 0 Manual revision 0 0 Date April 2008 ...
Страница 2: ......
Страница 47: ...MC Balance manual 44 General dimension MC Balance ME25G NST40 Neckpiece ...
Страница 48: ...MC Balance manual 45 General dimension MC Balance MV25G NST40 Neckpiece ...
Страница 49: ...MC Balance manual 46 General dimension MC Balance Support frame NST40 Neckpiece ...