![Movacolor MC-BALANCE Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/movacolor/mc-balance/mc-balance_user-manual_1841080037.webp)
MC-Balance manual
34
7.12 Alarms
GENERAL
To reset an alarm / warning press Stop or the menu button.
When an error occurs using the MC-Balance, the display will indicate an error code and
description.
Together with the displayed error an output contact will be switched.
The controller itself gives a beeping signal and the alarm LED will lighten up.
We distinguish Warning and Alarm:
Warning
:
Warning output is ON, but the dosing unit continues running
(24VDC contact, pin 22-23 of the main board will be active,
for example to activate the flash light,)
Alarm
:
Alarm output is ON and the
dosing unit stops running
(Potential free contact, pin 26-27 of the main board will be active, for example to
stop the Injection molding machine or extruder)
Free programmable errors can be configured to an
Alarm
or
Warning
.
For setting the free programmable outputs into alarm or warning, enter the ALARMS menu.
First the alarm history will be shown. The alarms and warnings will be stored inhere.
When you press the menu button again you will enter the alarm configuration menu.
Here you can set the alarm- or warning output with
and confirm.
ALARMHISTORY
All alarms and warnings will be stored in the alarm history.
•
Go to the ALARMS <menu>
•
Press
to scroll to the stored alarms (max.50).
The alarm history can be reset by the supervisor in CONFIGURATION <menu> by
•
Master reset: Alarm
We have the following Errors:
Error
Code
Warnings
00
Low hopper level
Material is below the hopper empty weight
01
Maximum deviation exceeded
The deviation of the material output is too high
02
Filling system unable to load material
Fill system is not working correct
03
Maximum RPM exceeded, change dosing
tool for higher capacity
Calculated motor speed is too high
05
Calibration, no weight change
No weight change while calibrating
06
Hi-Hi level
Hopper weight has reached the EX-HH level
07
Minimum motor speed < 0,1 RPM
Calculated motor speed is too low
Alarms
08
Motor connection failure
Motor not connected / Motor or connection damaged
09
Parameters damaged
Check configuration parameters
10
Parameters set to factory defaults
Check all parameter settings
11
Load cell calibration set to factory defaults Recalibrate the load cell
12
Job and curve database initialized
Jobs and Materials are reset
13
Load cell connection failure
Load cell connection is not correct
Содержание MC-BALANCE
Страница 1: ...MC Balance User Manual 4 0 UK 00 Software version V4 0 Manual revision 0 0 Date April 2008 ...
Страница 2: ......
Страница 47: ...MC Balance manual 44 General dimension MC Balance ME25G NST40 Neckpiece ...
Страница 48: ...MC Balance manual 45 General dimension MC Balance MV25G NST40 Neckpiece ...
Страница 49: ...MC Balance manual 46 General dimension MC Balance Support frame NST40 Neckpiece ...