6.4 Changing from Dosing cylinder to Feed screw
In relation to the maximum capacity of the dosing cylinder it might be necessary to change from
dosing cylinder to feed screw. As distinction from the dosing cylinder
t
he feed screw system is
consisting of a rotating screw in a
non
-rotating tube.
To install the feed screw perform to following steps:
1. Detach the motor quick release clamps and take out the motor from the hopper.
2. Dismount the neckpiece connection flange (1) by removing 4 socket-head screws.
3. For use with a dosing cylinder the neckpiece connection flange (1) is equipped with a ball
bearing. When using a feed screw system the ball bearing must be taken out. The metal ring
(2) which is fixed on the feed screw tube fits directly on the neckpiece connection flange.
4. Dismount the dosing cylinder (3) and mount the screw (4) with the M5 bolt.
5. Place back the motor + screw by closing the motor quick release clamps.
For cleaning the motor + screw can be easily be taken out.
POSSIBLE COMBINATIONS
1
3
4
2
Art.nr:H000010
Included seal
Art.nr:H000014
Included ball bearing
Art.nr:H000002
G / GL / H
GX / GLX / HX
A20
Содержание MC-BALANCE
Страница 1: ...MC Balance User Manual 4 0 UK 00 Software version V4 0 Manual revision 0 0 Date April 2008 ...
Страница 2: ......
Страница 47: ...MC Balance manual 44 General dimension MC Balance ME25G NST40 Neckpiece ...
Страница 48: ...MC Balance manual 45 General dimension MC Balance MV25G NST40 Neckpiece ...
Страница 49: ...MC Balance manual 46 General dimension MC Balance Support frame NST40 Neckpiece ...